Why the study?
Does B-mode, real-time ultrasonic imaging accurately detect atherosclerotic occlusive vascular disease compared to carotid angiography in patients evaluated for carotid disease?
Does B-mode, real-time ultrasonic imaging accurately detect atherosclerotic occlusive vascular disease compared to carotid angiography in patients evaluated for carotid disease?
Answers are grounded in this paper and cite their sources.
B-mode ultrasound has moderate sensitivity for detecting >50% stenosis and surgical disease, but low sensitivity for plaque ulceration and complete occlusion compared to angiography.
B-mode, real-time ultrasonic imaging was prospectively evaluated as a screening test for atherosclerotic occlusive vascular disease in the carotid bifurcation region, as defined by carotid angiography in 100 carotid systems in 50 patients. Preliminary reliability studies for each technique assessed agreement between examiners. Sensitivities of ultrasonography for stenosis greater than 50% of luminal diameter, complicated plaque ulceration, complete occlusion, and "surgical disease" by any of these parameters were 79%, 26%, 25%, and 73%, respectively. Thirty-seven percent of the 100 carotid systems were found to contain surgically relevant disease by angiography, compared with 19% and 56%, respectively, of the carotid systems with negative and positive ultrasonographic results. Judicious use of ultrasonography as a screen for angiography requires awareness of these limitations.
No takes yet. Share an insight, caveat, or question.
David C. Anderson (1983) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: