Why the study?
Does rigorous patient-prosthesis matching prevent severe patient-prosthesis mismatch in patients undergoing aortic valve replacement with the Perimount Magna bioprosthesis?
Does rigorous patient-prosthesis matching prevent severe patient-prosthesis mismatch in patients undergoing aortic valve replacement with the Perimount Magna bioprosthesis?
Rigorous patient-prosthesis matching during aortic valve replacement with the Perimount Magna bioprosthesis effectively prevents severe patient-prosthesis mismatch.
Rigorous matching may minimize severe mismatch with Perimount Magna AVR; leaves open outcome benefits pending prospective validation.
BACKGROUND: Severe patient-prosthesis mismatch, defined as effective orifice area index ≤0.65 cm(2) m(-2), has demonstrated poor long-term survival after aortic valve replacement. Reported rates of severe mismatch involving the Perimount Magna aortic bioprosthesis range from 4% to 20% in patients with a small annulus. METHODS: Between June 2008 and August 2011, 251 patients (mean age 70.5 ± 10.2 years; mean body surface area 1.55 ± 0.19 m(2)) underwent aortic valve replacement with a Perimount Magna bioprosthesis, with or without concomitant procedures. We performed our procedure with rigorous patient-prosthesis matching to implant a valve appropriately sized to each patient, and carried out annular enlargement when a 19-mm valve did not fit. The bioprosthetic performance was evaluated by transthoracic echocardiography predischarge and at 1 and 2 years after surgery. RESULTS: Overall hospital mortality was 1.6%. Only 5 (2.0%) patients required annular enlargement. The mean follow-up period was 19.1 ± 10.7 months with a 98.4% completion rate. Predischarge data showed a mean effective orifice area index of 1.21 ± 0.20 cm(2) m(-2). Moderate mismatch, defined as effective orifice area index ≤0.85 cm(2) m(-2), developed in 4 (1.6%) patients. None developed severe mismatch. Data at 1 and 2 years showed only two cases of moderate mismatch; neither was severe. CONCLUSIONS: Rigorous patient-prosthesis matching maximized the performance of the Perimount Magna, and no severe mismatch resulted in this Japanese population of aortic valve replacement patients.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: