Why the study?
Does the 19-mm Carpentier Edwards Perimount Magna bioprosthesis improve hemodynamics and left ventricular mass index regression compared to the 19-mm Medtronic Mosaic Ultra valve in patients with a small aortic annulus?
Does the 19-mm Carpentier Edwards Perimount Magna bioprosthesis improve hemodynamics and left ventricular mass index regression compared to the 19-mm Medtronic Mosaic Ultra valve in patients with a small aortic annulus?
The 19-mm Magna bioprosthesis provides satisfactory hemodynamics with lower LV-aortic pressure gradients than the Mosaic valve, though both yield similar LV mass index regression regardless of prosthesis-patient mismatch.
Answers are grounded in this paper and cite their sources.
Similar LV mass regression despite lower gradients with Magna should not yet change valve choice; leaves open whether hemodynamics affect long-term outcomes in small annuli.
BACKGROUND: When aortic valve replacement is performed in patients with a small aortic annulus, prosthesis-patient mismatch (PPM) is of concern because it can affect postoperative clinical outcomes. Although larger bioprosthetic valves have been well studied, the hemodynamics of 19-mm bioprostheses have been reported in only a small number of patients. The effectiveness as well as the impact of PPM on outcomes are thus still unclear. METHODS AND RESULTS: Postoperative clinical and hemodynamic variables were compared in 67 patients with a 19-mm Carpentier Edwards Perimount Magna bioprosthesis and in 10 patients with a 19-mm Medtronic Mosaic Ultra valve. Mean follow-up time was 13 months. There was no in-hospital mortality. Echocardiography 6.5±4.0 months after surgery showed significant decreases in the mean left ventricular (LV)-aortic pressure gradient, and decreases in the mean LV mass index. Reduction in LV mass index did not differ between the valve groups, despite a higher pressure gradient in the Mosaic group. Although PPM was detected in 21 patients in the Magna group, it did not affect regression of the LV mass index during the follow-up period. CONCLUSIONS: Use of the 19-mm Magna bioprosthesis appears to provide satisfactory clinical results. LV-aortic pressure gradient was lower in the Magna group. The present data suggest that PPM is not related to reduction in the LV mass index.
No takes yet. Share an insight, caveat, or question.
Okamura et al. (2011) studied this question.