Why the study?
Does TAVI with the self-expanding CoreValve device maintain long-term durability and prevent bioprosthetic valve failure in patients undergoing the procedure?
Does TAVI with the self-expanding CoreValve device maintain long-term durability and prevent bioprosthetic valve failure in patients undergoing the procedure?
TAVI with the self-expanding CoreValve demonstrates favorable long-term durability up to 8.9 years with low rates of bioprosthetic valve failure and no structural valve deterioration among survivors beyond 5 years.
Answers are grounded in this paper and cite their sources.
Supports CoreValve durability to 8 years in this cohort; leaves open need for randomized confirmation in broader populations.
AIMS: Long-term results of transcatheter aortic valve implantation (TAVI), in particular the incidence of bioprosthetic valve failure (BVF), are uncertain. This study presents data derived from a long-term, structured follow-up programme of the self-expanding CoreValve device utilising standardised definitions and core lab adjudication of valve performance. METHODS AND RESULTS: The study prospectively included all 152 patients who had undergone TAVI with the self-expanding CoreValve up to December 2011 at the Heart Center, Bad Segeberg, Germany. Late BVF (>30 days) was defined as either: 1) severe structural valve deterioration (transprosthetic mean pressure gradient ≥40 mmHg and/or ≥20 mmHg rise from baseline OR severe intraprosthetic aortic regurgitation), OR 2) bioprosthetic valve dysfunction leading to death or reintervention. Echocardiographic follow-up at 6.3±1.0 years (range: 5.0-8.9 years) was 88% complete (60 out of 68 survivors beyond five years) and all echocardiograms were analysed by an independent core laboratory. The all-cause mortality rate at 1, 2, 5, 6, 7 and 8 years was 14%, 20%, 50%, 60%, 65%, and 73%, respectively. Among survivors beyond five years, effective orifice area was 1.60±0.46 cm2, and transvalvular mean pressure gradient was 6.7±3.1 mmHg; no cases showed evidence of structural valve deterioration. Five patients (3.3%) had undergone redo TAVI (n=4) or surgery (n=1) 0.6 to 5.2 years after the index procedure, all due to paravalvular leakage. The estimated rate of BVF at eight years was 7.9% for the actuarial and 4.5% for the actual analysis. CONCLUSIONS: Long-term follow-up up to 8.9 years after TAVI documents favourable performance of the self-expanding CoreValve with low rates of BVF.
No takes yet. Share an insight, caveat, or question.
Holy et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: