Key result
IoTHolter platform achieves 0 packet loss during continuous LTE-M transmission of raw ECG signals.
Why the study?
Cardiovascular diseases are leading causes of mortality worldwide, making continuous ECG monitoring essential for early detection and follow-up of cardiac abnormalities.
The IoTHolter platform demonstrates reliable, continuous remote transmission of three-lead ECG signals via LTE-M cellular connectivity, providing a technical foundation for future portable Holter devices.
Answers are grounded in this paper and cite their sources.
May enable remote ECG monitoring; leaves open validation of accuracy and outcomes before clinical use.
Cardiovascular diseases are among the leading causes of mortality worldwide, making continuous electrocardiographic (ECG) monitoring essential for the early detection and follow-up of cardiac abnormalities. This study presents an Internet of Things (IoT) platform for continuous remote monitoring of three-lead ECG signals using LTE-M cellular connectivity. The proposed system integrates an ADS1293 analog front-end for ECG acquisition, a Walter IoT Module for MQTT-based data transmission, and a cloud infrastructure for secure data reception, storage, and visualization. A dual-core implementation on the ESP32 separates ECG acquisition from MQTT communication, preventing sample loss during continuous monitoring. Experimental results demonstrated reliable transmission of raw three-lead ECG signals, with no packet loss observed during a continuous 12 h LTE-M transmission test involving approximately 250,000 packets. The monitoring mechanism also automatically detected packet losses and device restarts. At the same time, server performance evaluation showed low CPU and memory utilization during simultaneous communication with five data sources under the evaluated conditions. These results validate the proposed IoT communication platform and establish a foundation for future work, including intelligent ECG analysis, improvements in signal acquisition and conditioning, and the continued development of the portable Holter device.
No takes yet. Share an insight, caveat, or question.
Escobedo-Carranza et al. (2026) studied Cardiovascular diseases. IoTHolter platform for continuous three-lead ECG monitoring was evaluated on Packet loss during continuous transmission. An IoT platform for continuous three-lead ECG monitoring demonstrated reliable transmission with 0% packet loss during a 12-hour LTE-M test involving approximately 250,000 packets.
Synapse has enriched 10 related papers. Consider them for comparative context: