Key result
The Czech version of the EHFScBS-9 is a valid and reliable instrument for measuring self-care behavior in heart failure patients, demonstrating good internal consistency with a Cronbach's alpha of 0.84.
Why the study?
To assess the validity and reliability of the Czech version of the European Heart Failure Self-Care Behaviour Scale (EHFScBS-9).
Cross-Sectional (n=130)
Yes
The Czech version of the EHFScBS-9 is a valid and reliable instrument for measuring self-care behavior in heart failure patients, facilitating its use in clinical practice and research.
Answers are grounded in this paper and cite their sources.
Supports Czech EHFScBS-9 for HF self-care assessment; extends validation to Czech patients but leaves outcome linkage open.
Aim. To assess validity and reliability of the Czech version of the European Heart Failure Self-Care Behaviour Scale (EHFScBS-9). Material and methods. 130 Czech heart failure (HF) patients accomplished the EHFScBS-9 and the Cardiac Self-Efficacy Questionnaire (CSEQ). Linguistic validation was performed. Item analysis, confirmatory factor analysis, and convergent validity were evaluated. Reliability was calculated by Cronbach’s alpha. Results. Based on fit criteria for the confirmatory factor analysis models, the results pointed to good fit for the two-factor model (χ2 = 40.59, p = 0.013; RMSEA = 0.077; CFI = 0.972; TLI = 0.956; GFI = 0.937), respectively for the three-factor solution (χ2 = 38.24, p = 0.017; RMSEA = 0.076; CFI = 0.974; TLI = 0.957; GFI = 0.943) of the Czech EHFScBS-9. Convergent validity was confirmed on the basis of a significant correlation (r = 0.31, p = 0.001) between the Czech EHFScBS-9 (standardised score) and the CSEQ. Internal consistency was confirmed by Cronbach’s alpha values for the whole instrument (0.84), as well as for “Consulting behaviour” subscale (0.90). The reliability of “adherence behaviours” subscale was questionable (0.59). Conclusions. The Czech version of the EHFScBS-9 is a valid and reliable instrument for measuring self-care behaviour in HF patients.
No takes yet. Share an insight, caveat, or question.
Soósová et al. (2025) conducted a cross-sectional in Heart failure (n=130). Czech version of the EHFScBS-9 was evaluated on Validity and reliability (Confirmatory factor analysis and Cronbach's alpha). The Czech version of the EHFScBS-9 is a valid and reliable instrument for measuring self-care behavior in heart failure patients, demonstrating good internal consistency with a Cronbach's alpha of 0.84.
Synapse has enriched 10 related papers. Consider them for comparative context: