Tissue-based 2D model optimisation closely fits experimental action potentials, enabling rhythmic 3D atrial excitation.
Answers are grounded in this paper and cite their sources.
Optimising generic cardiac ionic models within heterogeneous 2D tissue discs accounts for electrotonic coupling and enables realistic multiscale 3D simulations of spontaneous sinoatrial node pacemaking and whole-atrial propagation.
A 3D model of atrial electrical activity has been developed with spatially heterogeneous electrophysiological properties. The atrial geometry, reconstructed from the male Visible Human dataset, included gross anatomical features such as the central and peripheral sinoatrial node (SAN), intra-atrial connections, pulmonary veins, inferior and superior vena cava, and the coronary sinus. Membrane potentials of myocytes from spontaneously active or electrically paced in vitro rabbit cardiac tissue preparations were recorded using intracellular glass microelectrodes. Action potentials of central and peripheral SAN, right and left atrial, and pulmonary vein myocytes were each fitted using a generic ionic model having three phenomenological ionic current components: one time-dependent inward, one time-dependent outward, and one leakage current. To bridge the gap between the single-cell ionic models and the gross electrical behaviour of the 3D whole-atrial model, a simplified 2D tissue disc with heterogeneous regions was optimised to arrive at parameters for each cell type under electrotonic load. Parameters were then incorporated into the 3D atrial model, which as a result exhibited a spontaneously active SAN able to rhythmically excite the atria. The tissue-based optimisation of ionic models and the modelling process outlined are generic and applicable to image-based computer reconstruction and simulation of excitable tissue.
No takes yet. Share an insight, caveat, or question.
Abed et al. (2013) studied Atrial electrical activity and electrophysiology. 2D tissue-based parameter optimisation of generic single-cell ionic models incorporated into a 3D atrial model vs. Experimentally recorded action potentials and single-cell model optimisation was evaluated on Root mean square error (RMSE) between experimental and model-generated action potential waveforms, and 3D atrial pacemaking cycle length. Tissue-based 2D disc optimisation of generic ionic models fitted experimental action potentials with root mean square errors of 2.22 to 4.12 mV and enabled rhythmic 3D atrial excitation.
Synapse has enriched 10 related papers. Consider them for comparative context: