Answers are grounded in this paper and cite their sources.
This paper obtains analytical expressions for the calculation of the slot leakage inductance for fractional-slot concentrated-winding (FCSW) machines with one-, two-, or four-layer windings. The formulas are derived from solving the 2-D Poisson problem associated with the slot region, making them more accurate than classically used expressions that assume a leakage flux path parallel to the placement of the conductors in the slot. Explicit formulas are given in the case of one- and two-layer FSCWs with a number of phases ranging from 3 to 7. The obtained analytical expressions are validated by a finite-element analysis, showing excellent agreement between both calculation methods, even for large slot-opening-to-slot-pitch ratios. A brief comment with regard to the fault-tolerant capability of permanent-magnet FSCW machines with respect to the number of layers is also given.
No takes yet. Share an insight, caveat, or question.
Prieto et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: