Why the study?
Do dynamic volume parameters (GEDVI, SVV, PPV) better predict changes in cardiac index and stroke volume index compared to filling pressures (CVP, PCWP) in patients undergoing coronary artery bypass surgery?
Do dynamic volume parameters (GEDVI, SVV, PPV) better predict changes in cardiac index and stroke volume index compared to filling pressures (CVP, PCWP) in patients undergoing coronary artery bypass surgery?
Dynamic volume parameters (GEDVI, SVV, PPV) are superior to conventional filling pressures (CVP, PCWP) for predicting volume responsiveness in cardiac surgery patients under open-chest conditions.
Answers are grounded in this paper and cite their sources.
Dynamic parameters may better track cardiac index than filling pressures in open-chest CABG; hypothesis-generating, requiring RCTs before guiding therapy.
INTRODUCTION: Adequate fluid loading is the first step of hemodynamic optimization in cardiac patients undergoing surgery. Neither a clinical approach alone nor conventional parameters like central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) are thought to be sufficient for recognizing fluid deficiency or overload. The aim of this study was to evaluate the suitability of CVP, PCWP, global end-diastolic volume index (GEDVI), pulse pressure variation (PPV), and stroke volume variation (SVV) for predicting changes in the cardiac index (CI) and stroke volume index (SVI) after sternotomy. METHODS: In 40 patients, CVP, PCWP, GEDVI, PPV, SVV, and the CI were measured at two points of time. One measurement was performed after inducing anesthesia and one after sternotomy. RESULTS: A significant increase in heart rate, CI, and GEDVI was observed during the study period. CVP, SVV, and PPV decreased significantly. There were no significant correlations between CVP and PCWP and changes in CI. In contrast, GEDVI, SVV, and PPV significantly correlated with CI changes. Only relative changes of GEDVI, SVV, and PPV predicted changes in SVI. CONCLUSION: During cardiac surgery and especially after sternotomy, CVP and PCWP are not suitable for monitoring fluid status. Direct volume measurement like GEDVI and dynamic volume responsive measurements like SVV and PPV may be more suitable for monitoring the volume status of patients, particularly under open-chest conditions.
No takes yet. Share an insight, caveat, or question.
Sander et al. (2007) studied this question.