Why the study?
It was unknown whether changes in PPV and SVV following a tidal volume challenge can predict fluid responsiveness during protective mechanical ventilation under general anesthesia.
Does a 3-minute Tidal Volume Challenge (increasing tidal volume from 6 to 8 mL/kg IBW) accurately predict fluid responsiveness using changes in Pulse Pressure Variation and Stroke Volume Variation in adults undergoing non-cardiac surgery under protective mechanical ventilation?
Does a 3-minute Tidal Volume Challenge (increasing tidal volume from 6 to 8 mL/kg IBW) accurately predict fluid responsiveness using changes in Pulse Pressure Variation and Stroke Volume Variation in adults undergoing non-cardiac surgery under protective mechanical ventilation?
In patients undergoing non-cardiac surgery with lung-protective ventilation (6 mL/kg IBW), a temporary 3-minute increase in tidal volume to 8 mL/kg IBW (Tidal Volume Challenge) significantly improves the ability of PPV and SVV (>2% increase) to predict fluid responsiveness.
Answers are grounded in this paper and cite their sources.
May guide fluid decisions in non-cardiac surgery; supports VtC utility but leaves open randomized validation.
Background/Objectives: The aim of this study is to assess whether changes in Pulse Pressure Variation (PPV) and Stroke Volume Variation (SVV) following a VtC can predict the response to fluid administration in patients undergoing surgery under general anesthesia with protective mechanical ventilation. Methods: A total of 40 patients undergoing general surgery or vascular surgery without clamping the aorta were enrolled. Protective mechanical ventilation was applied, and the radial artery was catheterized in all patients. The protocol began one hour after the induction of general anesthesia and the stabilization of hemodynamic parameters. The parameters PPV6 and SVV6 were recorded during ventilation with a Vt of 6 mL/kg Ideal Body Weight (IBW) (T1). Then, the Vt was increased to 8 mL/kg IBW for 3 min without changing other respiratory parameters. After the VtC, the parameters PPV8 and SVV8 (T2) were recorded. After the stabilization of hemodynamic parameters, volume expansion (VE) was administered with colloid fluid of 6 mL/kg IBW. Parameters before (T3) and 5 min after fluid challenge (T4) were recorded. The change in the Stroke Volume Index (SVI) before and after VE was used to indicate fluid responsiveness. Patients were classified as fluid responders (SVI ≥ 10%) or non-responders (SVI < 10%). Results: The parameter ΔPPV(6–8) demonstrated good predictive ability to predict fluid responsiveness, evidenced by an Area Under the Curve (AUC) of 0.86 [95% Confidence Interval (CI) 0.74 to 0.95, p < 0.0001]. The threshold of ΔPPV(6–8) exceeding 2% identified responders with a sensitivity of 83% (95% CI 0.45 to 1.0, p < 0.0001) and a specificity of 73% (95% CI 0.48 to 1.0, p < 0.0001). The parameter ΔSVV(6–8) also revealed good predictive ability, reflected by an AUC of 0.82 (95% CI 0.67 to 0.94, p < 0.0001). The criterion ΔSVV(6–8) greater than 2% pinpointed responders with a sensitivity of 83% (95% CI 0.71 to 1.0, p < 0.001) and a specificity of 77% (95% CI 0.44 to 1.0, p < 0.001). Conclusions: This study demonstrates that VtC possesses good predictive ability for fluid responsiveness in patients undergoing general surgery.
No takes yet. Share an insight, caveat, or question.
Griva et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: