Left ventricular pacing via a coronary vein is a feasible, safe, and minimally invasive alternative for patients with prosthetic tricuspid valves who require permanent ventricular pacing.
Answers are grounded in this paper and cite their sources.
May offer alternative pacing approach in prosthetic tricuspid valve patients; hypothesis-generating and requires larger studies before adoption.
Transvenous endocardial pacemaker implantation is contraindicated in patients after prosthetic tricuspid valve replacement. A 65-year-old woman underwent both replacement of the mitral and tricuspid valves and pacemaker implantation with epicardial lead for bradycardia with chronic atrial fibrillation. At 2 years after this operation, the pacemaker's battery became low, and she was admitted for a battery exchange. To avoid frequent battery exchanges because of high stimulation thresholds, a left ventricular pacing lead was implanted via a coronary vein. There were no complications and the stimulation thresholds were stable. Coronary vein leads enable a minimally invasive approach, improve safety, and give effective stimulation for patients with a prosthetic tricuspid valve. This is the first case report in Japan of left ventricular pacing in such a patient.