Why the study?
Does chordal replacement with ePTFE sutures during mitral valve replacement prevent mortality and valve-related morbidity in patients with severe mitral stenosis?
Does chordal replacement with ePTFE sutures during mitral valve replacement prevent mortality and valve-related morbidity in patients with severe mitral stenosis?
Replacement of chordae tendineae using ePTFE sutures during mitral valve replacement for severe mitral stenosis appears safe with no mortality or valve-related morbidity in this small cohort.
Answers are grounded in this paper and cite their sources.
Supports safety of ePTFE chordal replacement in MVR; hypothesis-generating and requires larger prospective studies before practice change.
Since September 1991, 20 patients with mitral stenosis underwent mitral valve replacement and chordal replacement with expanded polytetrafluoroethylene (ePTFE) sutures. The continuity between the papillary muscles and the mitral annulus was maintained by four mattress sutures of ePTFE, which connected the stumps of the papillary muscle heads to the mitral annulus at the 2, 4, 8, and 10 o'clock positions. Low profile bileaflet prosthetic valves were inserted. There was no mortality either in-hospital or during follow-up. There was no valve related morbidity, such as valve structural failure, thromboembolism, anticoagulant related hemorrhage, prosthetic valve endocarditis, or posterior left ventricular rupture. The technique of replacing chordae tendineae is described in detail.
No takes yet. Share an insight, caveat, or question.
Okita et al. (1993) studied this question.