Why the study?
Does RT3DE with semiautomatic surface detection improve the quantification of LV mass compared to 2DE, using cardiac MR as the reference standard in patients?
Does RT3DE with semiautomatic surface detection improve the quantification of LV mass compared to 2DE, using cardiac MR as the reference standard in patients?
Direct three-dimensional model-independent LV mass measurement from RT3DE images provides fast and accurate assessment of LV mass, superior to two-dimensional analysis techniques.
Answers are grounded in this paper and cite their sources.
RT3DE may improve LV mass quantification accuracy versus 2DE; leaves open whether adoption alters management or outcomes.
OBJECTIVE: To develop a technique for volumetric analysis of real time three dimensional echocardiography (RT3DE) data aimed at quantifying left ventricular (LV) mass and to validate the technique against magnetic resonance (MR) assumed as the reference standard. DESIGN: RT3DE, which has recently become widely available, provides dynamic pyramidal data structures that encompass the entire heart and allows four dimensional assessment of cardiac anatomy and function. However, analysis techniques for the quantification of LV mass from RT3DE data are fundamentally two dimensional, rely on geometric modelling, and do not fully exploit the volumetric information contained in RT3DE datasets. Twenty one patients underwent two dimensional echocardiography (2DE), RT3DE, and cardiac MR. LV mass was measured from 2DE and MR images by conventional techniques. RT3DE data were analysed to semiautomatically detect endocardial and epicardial LV surfaces by the level set approach. From the detected surfaces, LV mass was computed directly in the three dimensional space as voxel counts. RESULTS: RT3DE measurement was feasible in 19 of 21 patients and resulted in higher correlation with MR (r = 0.96) than did 2DE (r = 0.79). RT3DE measurements also had a significantly smaller bias (-2.1 g) and tighter limits of agreement (2SD = +/-23 g) with MR than did the 2DE values (bias (2SD) -34.9 (50) g). Additionally, interobserver variability of RT3DE (12.5%) was significantly lower than that of 2DE (24.1%). CONCLUSIONS: Direct three dimensional model independent LV mass measurement from RT3DE images is feasible in the clinical setting and provides fast and accurate assessment of LV mass, superior to the two dimensional analysis techniques.
No takes yet. Share an insight, caveat, or question.
Enrico G. Caiani (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: