Key result
BioSTAR septal repair implant achieves ~96% shunt closure at 6 months.
Why the study?
Does the bioabsorbable BioSTAR septal repair implant safely and effectively close clinically significant ASD or PFO in adult patients?
Does the bioabsorbable BioSTAR septal repair implant safely and effectively close clinically significant ASD or PFO in adult patients?
The novel bioabsorbable BioSTAR septal repair implant is feasible and safe for ASD and PFO closure in humans, achieving a 96% closure rate at 6 months.
BACKGROUND: The use of permanent synthetic implants to close atrial septal defects (ASD) and patent foramen ovale (PFO) has a number of limitations, including late complications and the limiting of transeptal access to the left heart should it be required for the later treatment of acquired heart disease. BioSTAR is a novel, bioabsorbable, atrial septal repair implant. This phase I pilot study evaluates the feasibility, safety, and effectiveness of BioSTAR for the first time in humans. METHODS AND RESULTS: We conducted a prospective, open-label, multicenter clinical study in 58 patients aged 28 to 68 years who had a clinically significant ASD or PFO. Percutaneous shunt closure was undertaken with the BioSTAR septal repair implant. Successful device implantation was achieved in 57 (98%) of 58 patients. Closure at 30 days and 6 months, assessed by contrast transthoracic echocardiography, was 48 (92%) of 52 and 54 (96%) of 56, respectively. There was no evidence of a clinically significant response to the device. Transient atrial arrhythmia occurred in 5 patients after implantation. No major safety issues were observed. CONCLUSIONS: This study demonstrates the feasibility, safety, and effectiveness of BioSTAR for the closure of ASD and PFO in humans with a high rate of early and complete shunt closure. BioSTAR is a novel septal repair implant designed to provide biological closure of atrial-level defects using the patient's natural healing response. Because 90% to 95% of the implant is absorbed and replaced with healthy native tissue, future access to the left atrium may be achieved.
No takes yet. Share an insight, caveat, or question.
Mullen et al. (2006) studied Atrial septal defect (ASD) or patent foramen ovale (PFO) (n=58). BioSTAR septal repair implant was evaluated on Closure at 6 months assessed by contrast transthoracic echocardiography. Percutaneous shunt closure using the BioSTAR septal repair implant achieved successful implantation in 98% of patients and a 96% closure rate at 6 months.
Synapse has enriched one closely related paper. Consider it for comparative context: