Why the study?
Does magnesium sulfate infusion alter electrophysiologic parameters in normomagnesemic patients with cardiac conduction defects?
Does magnesium sulfate infusion alter electrophysiologic parameters in normomagnesemic patients with cardiac conduction defects?
Magnesium sulfate infusion in normomagnesemic patients with conduction defects causes a small but statistically significant prolongation of A-V and suprahisian conduction times without affecting intraventricular conduction.
Answers are grounded in this paper and cite their sources.
Magnesium infusion may subtly prolong AV conduction in normomagnesemic patients; hypothesis-generating and should not change practice without controlled data.
We report the electrocardiographic and electrophysiologic effects of magnesium (Mg) sulfate infusion in 25 normomagnesemic patients (16 men and 9 women, aged 22-74 years; mean +/- SD, 60.4 +/- 11.9) with different cardiac conduction impairments. Ten patients had chronic ischemic heart disease, two had idiopathic dilated cardiomyopathy, two had hypertensive heart disease, three had valvular heart disease, five had sclerodegenerative heart disease and three had no clinical evidence of cardiac disease. Five patients had trifascicular block [first degree atrioventricular (A-V) block+right bundle branch block (RBBB)+left anterior hemiblock (LAH)], eight had bifascicular block (6 RBBB+LAH, 2 first degree A-V block+RBBB), four had isolated first degree A-V block and eight had bundle branch block [5 RBBB, 3 left bundle branch block (LBBB)]. Before and during Mg infusion (50 mg/min/60 min) we evaluated the A-V (P-R), intraatrial (P-A), suprahisian (A-H), infrahisian (H-V) conduction times, electrical ventricular systole (Q-T), Q-T index (Q-Tc) intraventricular conduction time (QRS) and heart rate. At the end of infusion the P-R, P-A, A-H, H-V increased from 215.4 +/- 36.6, 33.6 +/- 9.1, 112.8 +/- 37.3, 69.0 +/- 12.8 ms to 217.6 +/- 37.1 (p less than 0.002), 33.8 +/- 9.4 (NS), 114.2 +/- 38.1 (p less than 0.005), 69.6 +/- 13.3 (NS) ms. QRS complex did not change (125 +/- 16.9 ms).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Perticone et al. (1992) studied this question.