Why the study?
Unattended automated office BP values are typically lower than conventional office measurements, but the factors responsible for this discrepancy remain poorly understood.
Does unattended automated office BP measurement compared to attended office BP measurement reduce blood pressure readings in hypertensive patients with anxiety?
Does unattended automated office BP measurement compared to attended office BP measurement reduce blood pressure readings in hypertensive patients with anxiety?
Unattended automated office BP measurement yields lower readings than attended measurement, with the discrepancy in systolic BP significantly driven by trait anxiety levels, highlighting its utility in mitigating the white coat effect.
Answers are grounded in this paper and cite their sources.
Anxiety may amplify OBP-UAOBP gaps; supports targeted UAOBP consideration in anxious patients but leaves practice change open.
BACKGROUND: Precision of blood pressure (BP) measurements is crucial in hypertension care. Conventional office measurements (OBP) are susceptible to confounding factors, including the white coat effect. An emerging alternative is unattended automated office BP measurement (UAOBP). UAOBP values are typically lower than OBP, but factors responsible for this phenomenon remain poorly understood. The study aimed to analyze factors affecting discrepancies between these methods. METHODS: Two hundred and nineteen hypertensive patients completed the State-Trait Anxiety Inventory questionnaire, assessing anxiety levels. Subsequently, BP measurements were performed using two methodologies in a randomized sequence:UAOBP: After a 5-minute rest in the examination room, BP was automatically measured three times at 1-minute intervals.OBP: Following a 5-minute rest, a physician performed three automated oscillometric measurements at 1-minute intervals. RESULTS: The BP values obtained through UAOBP were significantly lower than those in OBP: mean (SD) 124.7 (14.4) vs. 128.2 (14.2) mmHg, P < 0.001 for systolic, and 73.3 (10.2) vs. 75.2 (10.6) mmHg, P < 0.001 for diastolic. In the multiple regression analysis, the only factors significantly affecting the differences in systolic BP measurements were trait anxiety level (β = 0.22; P = 0.02) and the order in which the measurements were taken (β = 3.5; P = 0.01). Diastolic BP differences were only predicted by the order of measurement (β = 2.8; P < 0.001). CONCLUSIONS: UAOBP appears particularly efficient in mitigating the white coat effect in patients with high levels of anxiety. Further research is needed to investigate whether this may improve the assessment of BP-related risk in such patients.
No takes yet. Share an insight, caveat, or question.
Zięba et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: