The application of unattended blood pressure measurement (uAOBPM) for resting heart rate assessment was unknown.
Does unattended automated office blood pressure measurement (uAOBPM) provide accurate resting heart rate (RHR) agreement compared to standard office blood pressure measurement (OBPM), ambulatory blood pressure monitoring (ABPM), and resting electrocardiogram (ECG) in patients referred for ABPM?
Does unattended automated office blood pressure measurement (uAOBPM) provide accurate resting heart rate (RHR) agreement compared to standard office blood pressure measurement (OBPM), ambulatory blood pressure monitoring (ABPM), and resting electrocardiogram (ECG) in patients referred for ABPM?
Answers are grounded in this paper and cite their sources.
Resting heart rate measured during unattended automated office blood pressure measurement (uAOBPM) shows acceptable agreement with attended office measurements, daytime ABPM, and resting ECG, supporting its interchangeable use for routine heart rate assessment in clinical practice.
The application of unattended blood pressure measurement (uAOBPM) for resting heart rate (RHR) assessment is unknown. To assess the agreement between RHR measured during uAOBPM and other methods, the authors conducted a comparability study with office blood pressure measurement (OBPM), ambulatory blood pressure monitoring (ABPM), and electrocardiogram (ECG) in a group of 110 participants referred for ABPM. RHR measured with uAOBPM (70.8 ± 12.5 bpm) was significantly lower than OBPM (72.8 ± 12.6 bpm) but higher than measured by 24 h ABPM (67.5 ± 10.2 bpm). There was no significant difference was found between RHR measured by uAOBPM and daytime ABPM (70.3 ± 11.2 bpm) or ECG (69.1 ± 11.6 bpm). Using Bland-Altman statistics, the authors discovered a small difference in agreement between RHR measured by uAOBPM and daytime ABPM (bias: 0.4 with 95% confidence interval: -0.8 to 1.6 bpm), with a poorer agreement with OBPM (bias -2 with 95% confidence interval: -2.8 to -1.3 bpm) and ECG (bias 1.6 with 95% confidence interval: 0.5 to 2.7 bpm). The authors found significant agreement between uAOBPM and ECG in identifying subjects with RHR > 80 bpm OBPM, with Cohen's kappa coefficients of 0.783 and 0.671, respectively. Their findings indicate that RHR measured with uAOBPM remains in acceptable agreement with OBPM, ABPM, and ECG, the best agreement obtained with RHR from daytime ABPM.
No takes yet. Share an insight, caveat, or question.
Sobieraj et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: