Why the study?
Does propofol compared to isoflurane improve pulmonary mechanics and blood gases in patients with moderate to severe COPD undergoing anesthesia?
Does propofol compared to isoflurane improve pulmonary mechanics and blood gases in patients with moderate to severe COPD undergoing anesthesia?
Propofol and isoflurane have similar effects on pulmonary mechanics and oxygenation when used for anesthesia maintenance in patients with moderate to severe COPD, though they differ slightly in their effect on postoperative PaCO2.
Answers are grounded in this paper and cite their sources.
Supports either agent for maintenance anesthesia in moderate-severe COPD; confirms comparable pulmonary mechanics and oxygenation.
Patients with chronic obstructive pulmonary disease (COPD) are usually anesthetized with an inhalation agent. After Institutional Review Board approval, informed consent was obtained from 60 patients with moderate to severe COPD according to a preoperative severity scoring system, which took into account history and objective findings. By using objective criteria, such patients were randomly assigned to receive propofol (group I) or isoflurane (group II) as primary maintenance agents. Preoperative and postoperative arterial blood gases, peak expiratory flow rates (PEFR), and chest X-rays were compared. Total dynamic compliance (CDYN) and V1 (% volume exhaled in first second) were measured using Pitot tube sidestream spirometry. A 1,000-mL super-syringe was used to measure total static compliance (CST). Measurements were recorded postintubation, midanesthesia, and pre-extubation. All patients received fentanyl, lidocaine, and propofol, 1.5 to 2.0 mg/kg, for induction. Succinylcholine, 1-1.5 mg/kg, was administered to facilitate intubation. Maintenance was with N2O-O2, vecuronium, and either propofol (n = 30) or isoflurane (n = 30). Both groups showed decreases in postoperative PaO2, SaO2, and PEFR (p < 0.05), but there were no differences between groups (p > 0.05). There were no significant chest X-ray differences. There were no differences between groups with respect to intraoperative pulmonary mechanics (p > 0.05). The only difference between groups was an increase in postoperative PaCO2 in group I and a decrease in group II (p < 0.05). Use of Pitot tube sidestream spirometry is a practical and noninvasive technique for monitoring pulmonary mechanics during anesthesia.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
DeSouza et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: