Why the study?
Compressed sensing cines can include retrospective temporal resolution interpolation to improve frame count per heartbeat, but its impact on biventricular functional measurements was unknown.
Does retrospective temporal resolution interpolation (INTP TR) alter myocardial strain quantification and volumetry on compressed sensing cine CMR in patients undergoing cardiac imaging?
Does retrospective temporal resolution interpolation (INTP TR) alter myocardial strain quantification and volumetry on compressed sensing cine CMR in patients undergoing cardiac imaging?
Retrospective temporal resolution interpolation on compressed sensing cine CMR significantly underestimates peak strain and impairs strain rate analysis, indicating that feature tracking should be performed on non-interpolated data, although volumetry and ejection fraction remain consistent.
Answers are grounded in this paper and cite their sources.
INTPTR alters strain quantification on CS cines; leaves open standardization needs before routine clinical or research adoption.
Compressed sensing (CS) is a rapidly developing technique that can acquire functional cines of the heart within seconds while free-breathing and it is ideal for assessing cardiac function in non-typical conditions such as when patients are sedated or anaesthetized or undergoing stress exams. CS cines can further include retrospective temporal resolution interpolation (INTP TR ) to improve the frame count per heartbeat, and the impact of INTP TR on biventricular functional measurements is unknown. We investigated the impact of INTP TR on left and right ventricular volumetry and strain measurements of CS cines. Nineteen patients with 51 different CS acquisitions were prospectively enrolled. CS cines were acquired at rest, under adenosine stress, oxygen inhalation or while under general anaesthesia with mechanical ventilation. From the same CS acquisition, a dataset with and without INTP TR were generated by the scanner. The outputs were separated and analysed by blinded readers for left and right ventricular volumetry, as well as systolic and diastolic strain parameters using feature-tracking techniques. Measurements were compared between the INTP TR and non-INTP TR outputs. Similar measurements were obtained for biventricular volumes and ejection fraction independent of INTP TR . Peak strain was significantly underestimated on INTP TR cines for both longitudinal and circumferential orientations ( p < 0.01). Nevertheless, good-to-excellent correlations were observed between the two measurements ( r > 0.65, p < 0.01), and there was still a high area under the curve (AUC ≥ 0.95, p < 0.01) for detecting abnormal patients defined by strain analysis on the standard segmented cine. INTP TR especially negatively influenced strain rates analysis, as many strain rate curves were deemed unusable with this technique. These findings were consistent independent if the patient was in a resting, stress or anaesthetized condition. Although INTP TR is a feature which improves temporal resolution on CS cines, quantification of biventricular strain and strain rates is not feasible or comparable, thus, feature tracking analysis should be performed on non-INTP TR data. However, volumetry and ejection fraction analysis are consistent independent of which output is analysed.
No takes yet. Share an insight, caveat, or question.
Grob et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: