Why the study?
CT imaging analysis of the mitral annulus, coronary sinus, and left circumflex artery is critical to transcatheter mitral annuloplasty, but is scantly reported.
Does cardiac CT-based 3-D reconstruction reveal differences in mitral annulus, coronary sinus, and left circumflex artery geometry between patients with and without mitral regurgitation?
Does cardiac CT-based 3-D reconstruction reveal differences in mitral annulus, coronary sinus, and left circumflex artery geometry between patients with and without mitral regurgitation?
Answers are grounded in this paper and cite their sources.
Comprehensive 3-D CT analysis reveals significant geometric differences in the mitral apparatus between primary and secondary MR, which may inform the design and application of transcatheter mitral annuloplasty devices.
INTRODUCTION: CT imaging analysis of mitral annulus (MA), coronary sinus (CS) and left circumflex artery (LCX) is critical to transcatheter mitral annuloplasty (TMA), which, however, is scantly reported. We aimed to comprehensively assess MA, CS and LCX anatomy and geometry in mitral regurgitation (MR) based on 3-D reconstruction of cardiac CT images. METHODS: Patients with primary or secondary MR and patients without MR were recruited and underwent cardiac CT examination. MR severity was evaluated by echocardiography. 3-D reconstruction of cardiac CT images was done by the Mimics Research 21.0 software. A MA-centered two dimensional coordinate system, a CS plane, a MA plane and a series of auxiliary planes along the posterior MA were created for the measurement of parameters defining MA, CS and LCX anatomy and geometry during the cardiac cycle. RESULTS: The secondary MR group had a significantly higher MA perimeter index than the other two groups during the cardiac cycle. The CS diameters at most sites, and the posterior MA radian were substantially greater in the two MR groups. Distances between the CS and MA at some locations were significant different among the three groups. The secondary MR group had a significantly smaller CS-MA plane angle than the other two groups during systole, and than control group during diastole. The site where the CS crossed LCX was pinpointed. CONCLUSION: The comprehensive information from this study may help improve the results of TMA and enhance the design of devices for a better annuloplasty effect.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2023) studied this question.