Why the study?
Achieving reproducible exercise CMR measurements has been challenging due to limited spatial and temporal resolution.
AI-enhanced free-breathing single-beat exercise CMR provides highly reproducible biventricular volumetric and functional measurements.
AI-enhanced free-breathing Ex-CMR cine is feasible in a cohort; leaves open diagnostic accuracy and clinical utility pending prospective validation.
BACKGROUND: Exercise cardiovascular magnetic resonance (Ex-CMR) can reveal pathophysiologies not evident at rest by quantifying biventricular volume and function during or immediately after exercise. However, achieving reproducible Ex-CMR measurements is challenging due to limited spatial and temporal resolution. This study aimed to develop and evaluate a free-breathing, high-spatiotemporal-resolution single-beat Ex-CMR cine enhanced by generative artificial intelligence. We assessed image analysis reproducibility, scan-rescan reproducibility, and impact of the reader's experience on the analysis. METHODS: Imaging was performed on a 3T CMR system using a free-breathing, highly accelerated, multi-slice, single-beat cine sequence (in-plane spatiotemporal resolution of 1.9 × 1.9 mm² and 37 ms, respectively). High acceleration was achieved by combining compressed sensing reconstruction with a resolution-enhancement generative adversarial inline neural network. Ex-CMR was performed using a supine ergometer positioned immediately outside the magnet bore. Single-beat cine images were acquired at rest and immediately post-exercise. In a prospective study, the protocol was evaluated in 141 subjects. A structured image analysis workflow was implemented. Four expert readers, with or without prior training in single-beat Ex-CMR, independently rated all images for diagnostic and image quality. The subjective assessment used two 3-point Likert scales. Biventricular parameters were calculated. Inter- and intra-observer reproducibility were assessed. Fifteen healthy subjects were re-imaged 1 year later for scan-rescan reproducibility. Reproducibility was assessed using intraclass correlation coefficient (ICC), with agreement evaluated via Bland-Altman analysis, linear regression, and Pearson correlation. RESULTS: Free-breathing, single-beat Ex-CMR cine enabled imaging of the beating heart within 30 ± 6 s, with technically successful scans in 96% (136/141) of subjects. Post-exercise single-beat cine images were assessed as diagnostic in 98% (133/136), 96% (131/136), 82% (112/136), and 65% (89/136) of cases by four readers (ordered by descending years of Ex-CMR experience). Good image quality was reported in 74% (100/136) to 80% (109/136) of subjects. Biventricular parameters were successfully measured in all subjects, demonstrating good to excellent inter-observer reproducibility. Scan/rescan reproducibility over 1 year, assessed by two independent readers, showed excellent inter-visit ICCs (0.96-1.0) and strong correlations (R² ≥ 0.92, p < 0.001 for left ventricle; R² ≥ 0.95, p < 0.001 for right ventricle). CONCLUSION: Single-beat Ex-CMR enabled evaluation of biventricular volumetric and functional indices with excellent reproducibility.
No takes yet. Share an insight, caveat, or question.
Ghanbari et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: