Key result
Fine-tuned GPT-4o vision detects low LVEF with ~80% accuracy, beating clinicians but trailing dedicated CNNs.
Why the study?
Echocardiography for assessing LVEF may not always be readily available, and specialized AI models using ECG are often complex and costly to develop.
Does GPT-4o Fine-Tuned Vision accurately detect LVEF ≤ 35% from ECG images compared to a specialized CNN model and clinician assessments in adult patients?
Cross-Sectional (n=202)
No
Does GPT-4o Fine-Tuned Vision accurately detect LVEF ≤ 35% from ECG images compared to a specialized CNN model and clinician assessments in adult patients?
Answers are grounded in this paper and cite their sources.
GPT-4o Fine-Tuned Vision demonstrates feasibility as an accessible, general-purpose AI tool for detecting reduced LVEF from ECGs, outperforming average clinicians but trailing specialized CNNs, though its clinical reasoning remains flawed.
BACKGROUND: Assessing Left Ventricular Ejection Fraction (LVEF) is crucial for diagnosing reduced systolic function, yet echocardiography (ECHO) may not always be readily available, potentially delaying treatment. Electrocardiography (ECG) offers a cost-effective and accessible alternative for estimating LVEF. However, specialized AI models for this purpose are often complex and costly to develop. OBJECTIVE: This study uniquely evaluates GPT-4o Fine-Tuned Vision (GPT-4o-FTV), a general-purpose AI model, for detecting LVEF ≤ 35% from ECG images, comparing its performance with a Convolutional Neural Network (CNN) model and clinician assessments. METHODS: We analyzed ECGs from 202 patients (42.6% women, mean age 64.5 ± 16.3 years) at a tertiary center, excluding those with pacemakers and including only high-quality ECGs. LVEF ≤ 35% was present in 11.9% (n = 24). GPT-4o-FTV, trained on 20 labeled ECGs, was tested using a structured prompt across four runs. Accuracy, sensitivity, specificity, and positive predictive value (PPV) were compared to a CNN model and four clinicians. RESULTS: GPT-4o-FTV achieved 79.9% accuracy, 72.9% sensitivity, 80.8% specificity, an F1-score of 46.4%, and a PPV of 34%, outperforming clinicians (74.9% accuracy, 65.6% sensitivity, 76.1% specificity, 39% F1-score, PPV 27.9%). The CNN model had the highest performance (89.1% accuracy, 79.2% sensitivity, 90.4% specificity, 63.3% F1-score, PPV 52.8%). CONCLUSIONS: GPT-4o-FTV demonstrates strong potential as an accessible tool for cardiac diagnostics, particularly in resource-limited settings. While CNN models remain superior in accuracy, the ease of fine-tuning GPT-4o-FTV highlights its practical utility. Future research should focus on larger datasets, additional optimization, and exploring its ability to detect early predictors of LVEF decline.
No takes yet. Share an insight, caveat, or question.
Engelstein et al. (2025) conducted a cross-sectional in Reduced Left Ventricular Ejection Fraction (LVEF ≤ 35%) (n=202). GPT-4o Fine-Tuned Vision vs. Convolutional Neural Network (CNN) and clinician assessments was evaluated on Accuracy in detecting LVEF ≤ 35% (95% CI 0.77-0.83, p=0.0049). GPT-4o Fine-Tuned Vision achieved 79.9% accuracy in detecting LVEF ≤ 35% from ECG images, outperforming average clinician assessments but remaining inferior to a specialized CNN model.
Synapse has enriched 10 related papers. Consider them for comparative context: