Why the study?
The study aimed to develop an artificial intelligence-based method to screen patients with LVEF of 50% or lesser using ECG data alone.
Does a CNN algorithm applied to 12-lead ECG data accurately identify left ventricular dysfunction (LVEF ≤ 50%) compared to TTE?
Does a CNN algorithm applied to 12-lead ECG data accurately identify left ventricular dysfunction (LVEF ≤ 50%) compared to TTE?
A CNN algorithm applied to standard 12-lead ECGs can identify left ventricular dysfunction with moderate accuracy, offering a potential low-cost, noninvasive screening tool.
Answers are grounded in this paper and cite their sources.
CNN-ECG screening for LVEF ≤50% is feasible retrospectively; leaves open prospective validation before clinical use.
OBJECTIVE: This study aims to develop an artificial intelligence-based method to screen patients with left ventricular ejection fraction (LVEF) of 50% or lesser using electrocardiogram (ECG) data alone. METHODS: Convolutional neural network (CNN) is a class of deep neural networks, which has been widely used in medical image recognition. We collected standard 12-lead ECG and transthoracic echocardiogram (TTE) data including the LVEF value. Then, we paired the ECG and TTE data from the same individual. For multiple ECG-TTE pairs from a single individual, only the earliest data pair was included. All the ECG-TTE pairs were randomly divided into the training, validation, or testing data set in a ratio of 9:1:1 to create or evaluate the CNN model. Finally, we assessed the screening performance by overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value. RESULTS: We retrospectively enrolled a total of 26 786 ECG-TTE pairs and randomly divided them into training (n = 21 732), validation (n = 2 530), and testing data set (n = 2 530). In the testing set, the CNN algorithm showed an overall accuracy of 73.9%, sensitivity of 69.2%, specificity of 70.5%, positive predictive value of 70.1%, and negative predictive value of 69.9%. CONCLUSION: Our results demonstrate that a well-trained CNN algorithm may be used as a low-cost and noninvasive method to identify patients with left ventricular dysfunction.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: