Autopsy findings of post-valvular replacement deaths highlight acute hemorrhagic and chronic collagenization changes in the conduction system, alongside other severe complications.
Answers are grounded in this paper and cite their sources.
Post-valve replacement autopsies show conduction hemorrhages and collagenization; leaves open incidence, mechanisms, and prevention in broader cohorts.
Five interesting autopsy cases of post-valvular replacement death are reported and discussed with special reference to disturbances of the conduction system. The most important acute changes are hemorrhages; the significance of a venous hemorrhage is emphasized. Chronic changes are collagenization of conduction system. One case of mycotic valvulitis, probably due to aspergillus, and one case of dissecting aneurysm probably related to previous valve replacement surgery are included.
No takes yet. Share an insight, caveat, or question.
Tomaru et al. (1975) studied this question.