Key result
Artificial valve replacement in 86 patients resulted in an early mortality rate of 25.5% and a late mortality rate of 11.6%, with most survivors improving to functional class II or III.
Observational (n=86)
No
In this early historical cohort from Japan, artificial valve replacement carried a high initial mortality (25.5% early death) but provided significant functional improvement for survivors.
Answers are grounded in this paper and cite their sources.
High early mortality in this historical cohort cautions against extrapolation today; leaves open questions on contemporary valve outcomes.
We had 49 cases of mitral valve replacement. Aortic valve replacement has been performed 30 cases. Double valve replacement was performed in 7 cases, which were all serious.94 artificial valve were used in the valve replacement of our cases, and 61 of them were a ball valve of Starr-Edwards. 26 were a disc valve of SAKAKIBARA (SAM).Postoperatively, anticoagulant treatment was given to all cases. On the surgical result of our artificial valve replacement, early death was seen in 22 (25.5%) and late death in 10 (11.6%) of 86 cases.Postoperative complication and cause of death were low cardiac output syndrome, hemorrhage, pulmonary edema, infection and embolism. On the Pre and postoperative changes of functional capacity by NYHA, the most of cases were improved to II or III grade.
No takes yet. Share an insight, caveat, or question.
Ohishi et al. (1971) conducted an observational in Valvular heart disease (n=86). Artificial valve replacement was evaluated on Early and late mortality. Artificial valve replacement in 86 patients resulted in an early mortality rate of 25.5% and a late mortality rate of 11.6%, with most survivors improving to functional class II or III.
Synapse has enriched 10 related papers. Consider them for comparative context: