Why the study?
Does intravenous prenalterol affect central haemodynamics and VA/Q distribution in patients early after aortic and/or mitral valve replacement?
Does intravenous prenalterol affect central haemodynamics and VA/Q distribution in patients early after aortic and/or mitral valve replacement?
Answers are grounded in this paper and cite their sources.
Intravenous prenalterol increases cardiac output and heart rate early after valve replacement surgery, but also increases pulmonary shunting likely secondary to the increased cardiac output.
The effects of intravenous injection of prenalterol, a selective beta 1-adrenoceptor agonist, on central haemodynamics and the distribution of ventilation-perfusion (VA/Q) were assessed in eight patients after aortic and/or mitral valve replacement. VA/Q distributions were determined by the multiple inert gas elimination technique. Administration of prenalterol resulted in a significant increase in cardiac output and heart rate with no changes in mean pulmonary arterial pressure and wedge pressure. There was an insignificant fall in arterial oxygen tension from 14.3 to 12.4 kPa, accompanied by a significant increase in the inert gas shunt from 6.4 to 11.3% of cardiac output, while the configuration of the distribution of perfusion and ventilation on VA/Q remained unchanged. The increase in shunt was probably more an effect of the increase in cardiac output than a direct effect of the drug on the pulmonary vascular bed.
No takes yet. Share an insight, caveat, or question.
Anjou‐Lindskog et al. (1983) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: