Biomechanical study demonstrates higher ultimate tensile strength for asymmetric six-strand repair in porcine tendons, suggesting improved clinical performance.
BACKGROUND: This study evaluated the biomechanical performance of a novel asymmetric 6-strand flexor tendon repair technique without locking loops. METHODS: Twenty porcine flexor tendons were equally repaired by using the asymmetric technique and compared with the modified Lim-Tsai repair technique. The ultimate tensile strength, load to 1-mm gap force, stiffness, and mechanism of failure were measured. RESULTS: The asymmetric repair technique had significantly higher tensile strength (63.3 ± 3.7 N) than the modified Lim-Tsai repairs (46.7 ± 8.3 N). CONCLUSIONS: A novel flexor tendon repair technique with improved biomechanical performance may be available for use in flexor tendon repairs.
No takes yet. Share an insight, caveat, or question.
Wong et al. (2017) studied this question.