Why the study?
Concomitant epicardial ablation of VT remains clinically challenging due to intra-operative mapping requirements, and no 3D printing material or technique has met the needs for a patient-tailored guide.
High-consistency rubber silicone molding is a feasible method for creating patient-specific epicardial guides for VT ablation that can withstand surgical sterilization and ablation energies.
Answers are grounded in this paper and cite their sources.
May enable customized VT ablation guides in surgery; leaves open clinical efficacy and workflow impact in larger studies.
BACKGROUND: Concomitant epicardial ablation of ventricular tachycardia (VT) remains a clinical challenge in cardiac surgery due to the need for intra-operative mapping. A preoperative patient-tailored epicardial guide could provide an intraoperative 'blueprint' of arrhythmogenic target substrate, thereby facilitating the workflow. Thus far, no 3D printing material or technique has fully met the requirements for this application. This study explores the feasibility of high-consistency rubber (HCR) silicone molding to produce low-cost, customized guides for VT scar ablation. METHODS: An inverted mold was created in Meshmixer using merged LGE-CMR and cardiac CT images of a 61-year-old VT patient, and printed using fused deposition modeling. HCR silicone was milled, sculpted, and trimmed to fit the negative mold. The guide was cured, subjected to autoclaving, and bench-tested on an ex vivo porcine heart model using radiofrequency and cryo-ablation. Various durometers and thicknesses were tested to determine the optimal fit for our application. RESULTS: MED-4072 and MED-4080 silicone (thickness range: 2.0-3.4 mm). Models with 2.1-3.0 mm thickness and 70 Shore A hardness achieved the best balance between flexibility and rigidity for application on a beating heart. The thinnest model (2.0 mm) was too pliable for stable placement. The guides withstood autoclaving and ablation procedures (radiofrequency; cryo-energy) without deformation or compromising structural integrity. CONCLUSIONS: The HCR silicone molding technique allows for the production of flexible, cost-effective epicardial guides for VT ablation, minimizing the need for a full electrophysiology team throughout the entire procedure.
No takes yet. Share an insight, caveat, or question.
Kronenberger et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: