Why the study?
Is the Evolution mechanical dilator sheath safe and effective for the transvenous extraction of pacemaker and ICD leads?
Is the Evolution mechanical dilator sheath safe and effective for the transvenous extraction of pacemaker and ICD leads?
Answers are grounded in this paper and cite their sources.
The Evolution mechanical dilator sheath provides high clinical and procedural success rates for extracting older pacemaker and ICD leads, though the risk of major complications necessitates cardiovascular surgery backup.
OBJECTIVE: In recent years there has been an increase in clinical situations requiring lead extraction procedures of implanted cardiac devices. In our clinic, extraction procedures are performed with Evolution® mechanical lead extraction system. In this manuscript we aimed to evaluate our lead extraction procedures. METHODS: We retrospectively evaluated lead extraction procedures carried out on 41 patients [30 male, 11 female patient; mean age 61.5 ± 18.5 median 67 (23-85)] between 2008 and 2015 using Evolution® system. Procedural success, major and minor complications are determined according to previously published guidelines. RESULTS: Mean duration of the lead implantation was 88.4 ± 62.5 months (6-240). Implanted device was a pacemaker in 27 (65.8 %) and ICD in 14 (34.2 %) of patients. Total 67 leads were extracted from the patients, 22 (32.8 %) were atrial, 30 (44.2 %) were ventricular, 14 (21.5 %) were dual coil defibrillator and 1 (1.5 %) was coronary sinus lead. Indications for lead removal were pacemaker decubitis and infection in 29 (70.8 %), lead dysfunction in 11 (26.8 %) and subclavian vein thrombosis in 1 (2.4 %) patient. Success rate with Evolution® system without using snare was 85.3 %. Clinical success rate was 97.5 % procedural success rate was 95.1 % and failure occured in one patient. Major complications occured in 2 (4.8 %) patients, 1 (2.4 %) was procedure related mortality. Minor complications were seen in 5 (12.2 %) of patients. CONCLUSIONS: In our single center study it is shown that extraction of pacemaker and defibrillator leads of relatively long implantation duration and in an older age patient group may be successfully carried out using the Evolution® system. However due to potentially serious complications it is adviced to be done by experienced operators in centers with cardiovascular surgery backup.
No takes yet. Share an insight, caveat, or question.
Kocabaş et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: