Why the study?
Does ICD lead explantation compared to abandonment increase in-hospital complications and death in patients with unused or malfunctioning ICD leads?
Does ICD lead explantation compared to abandonment increase in-hospital complications and death in patients with unused or malfunctioning ICD leads?
In patients with unused or malfunctioning ICD leads, a strategy of lead explantation is associated with slightly higher in-hospital complications and mortality compared to lead abandonment, with no significant difference in 1-year mortality or 6-month complications.
Answers are grounded in this paper and cite their sources.
Supports caution with explantation due to higher in-hospital risks; leaves open long-term strategy for unused ICD leads.
BACKGROUND: Patients with an unused or malfunctioning implantable cardioverter-defibrillator (ICD) lead may have the lead either abandoned or explanted; yet there are limited data on the comparative acute and longer-term safety of these 2 approaches. METHODS AND RESULTS: We examined in-hospital events among 24 908 subject encounters using propensity score 1:1 matching for ICD lead abandonment or explantation in the National Cardiovascular Data Registry (NCDR) ICD Registry (April 2010 to June 2014). Relative to patients undergoing lead abandonment, patients undergoing lead explantation had more in-hospital procedure-related complications: 2.19% (n=273) versus 3.77% (n=469; P<0.001), respectively. Similarly, patients undergoing lead explantation had slightly higher rates of in-hospital death: 0.21% (n=26) versus 0.64% (n=80; P<0.001), respectively. At 1 year in a Medicare subset for survival, there was a trend of increased mortality in the explantation group (11% versus 8%; P=0.06). In the Medicare subset analyzed for postprocedure complications, there was no difference with respect to 6-month bleeding (4.80% in both the groups), tamponade (0.38% versus 0.58%), infection (1.34% versus 3.07%), upper extremity thrombosis (0.77% versus 0.96%), pulmonary embolism (0.38% versus 0.96%), or urgent surgery (1.15% for both the groups; P>0.05 for all). CONCLUSIONS: After matching, patients undergoing removal of an unused or malfunctioning ICD lead had slightly higher in-hospital complications and deaths than those with a lead abandonment strategy. Although the 1-year mortality risk was slightly higher in the lead explantation group, this difference was not statistically significant and may be explained by chance.
No takes yet. Share an insight, caveat, or question.
Zeitler et al. (2016) studied this question.