Key result
Postoperative severe MR but not AF recurrence links to ~154% higher mortality after mitral repair.
Why the study?
The study examined the associations of structural and electrical failure with long-term survival after mitral repair with atrial fibrillation ablation for degenerative mitral prolapse using time-dependent modeling.
Does structural failure (severe MR) or electrical failure (AF recurrence) increase long-term mortality in patients undergoing mitral valve repair and concomitant AF ablation for degenerative mitral prolapse?
Cohort (n=300)
No
Does structural failure (severe MR) or electrical failure (AF recurrence) increase long-term mortality in patients undergoing mitral valve repair and concomitant AF ablation for degenerative mitral prolapse?
In patients undergoing mitral valve repair and AF ablation for degenerative prolapse, structural valve failure (severe MR) is independently associated with long-term mortality, whereas electrical failure (AF recurrence) is not.
Answers are grounded in this paper and cite their sources.
Structural or electrical failure after mitral repair plus AF ablation may influence survival; leaves open need for confirmatory randomized data.
Background: We examined associations of structural and electrical failure with long-term survival after mitral repair with atrial fibrillation (AF) ablation for degenerative mitral prolapse, using time-dependent modeling. Methods: We analyzed 300 consecutive patients (age, 59.4±11.9 years; 34.7% female) undergoing degenerative mitral prolapse repair with surgical ablation. Structural failure was defined as postoperative severe mitral regurgitation (MR); electrical failure was defined as AF recurrence beyond a 3-month blanking period. Structural and electrical failures were modeled as time-varying covariates in Cox proportional hazards models evaluating mortality. Bidirectional time-dependent and landmark analyses assessed temporal interdependence. Results: During follow-up (median, 6.3 years), structural and electrical failures occurred at 4.1% and 5.7% per patient-year, respectively; death occurred at 1.1%/patient-year. Structural failure was independently associated with tricuspid regurgitation (TR) velocity (adjusted hazard ratio [aHR], 2.94; 95% confidence interval [CI], 1.79-4.83) and anterior leaflet prolapse (aHR, 3.10; 95% CI, 1.18-8.12). Electrical failure was independently associated with age (aHR, 1.53; 95% CI, 1.19-1.98), left atrial diameter (aHR, 1.06; 95% CI, 1.04-1.08), and severe TR (aHR, 6.24; 95% CI, 2.15-18.11). In the time-dependent analysis, severe MR independently predicted mortality (aHR, 2.54; 95% CI, 1.01-6.38), whereas AF recurrence did not (aHR, 0.97; 95% CI, 0.24-3.97). Bidirectional analyses showed no significant temporal association between structural and electrical failures. Conclusion: Among patients with degenerative mitral prolapse undergoing mitral repair with concomitant AF ablation, structural valve failure, but not electrical recurrence, was associated with increased long-term mortality. Structural and electrical failures showed no significant temporal association.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) conducted a cohort in Degenerative mitral valve disease with atrial fibrillation (n=300). Postoperative severe mitral regurgitation (structural failure) vs. No severe mitral regurgitation was evaluated on All-cause mortality (aHR 2.54, 95% CI 1.01-6.38, p=0.048). Postoperative severe mitral regurgitation was independently associated with increased long-term mortality after mitral repair with AF ablation, whereas AF recurrence was not.
Synapse has enriched 10 related papers. Consider them for comparative context: