Key result
Patients with stress-related mental disorders exhibited a flattened age-related decline in the low-versus-high frequency EEG power ratio and higher pre-sleep heart rate compared to healthy controls.
Why the study?
Stress-related mental disorders are characterized by disturbed sleep, but objective sleep biomarkers are not routinely evaluated in psychiatric patients.
Cross-Sectional (n=83)
Wearable EEG and PPG devices can detect objective sleep microarchitecture differences, such as altered age-related cortical hyperarousal and pre-sleep sympathetic drive, in patients with stress-related mental disorders.
Answers are grounded in this paper and cite their sources.
Wearable EEG/PPG may detect sleep alterations in stress disorders; hypothesis-generating and requires prospective validation before clinical use.
Study Objectives Several stress-related mental disorders are characterized by disturbed sleep, but objective sleep biomarkers are not routinely examined in psychiatric patients. We examined the use of wearable-based sleep biomarkers in a psychiatric sample with headband electroencephalography (EEG) including pulse photoplethysmography (PPG), with an additional focus on microstructural elements as especially the shift from low to high frequencies appears relevant for several stress-related mental disorders (cortical hyperarousal). Methods We acquired 483 nights and could analyze 372 nights of sufficient quality from 83 healthy participants and those with a confirmed stress-related mental disorder (anxiety-affective spectrum). We analyzed the data with respect to macrostructural and microstructural characteristics according to the newly described spectral slope fitting over the whole frequency spectrum. Results The headbands were accepted well by patients and the data quality was sufficient for most nights. The macrostructural analyses revealed trends for significance regarding sleep continuity but not sleep depth variables. The spectral analyses yielded no between-group differences except for a group × age interaction, with the normal age-related decline in the low versus high frequency power ratio flattening in the patient group. PPG analyses showed that the mean heart rate was higher in the patient group in pre-sleep epochs, a difference that reduced during sleep and dissipated at wakefulness. Conclusions Wearable devices that record EEG and/or PPG could be used over multiple nights to assess relevant markers such as sleep fragmentation, cortical hyperarousal, and sympathetic drive throughout the sleep–wake cycle in patients with stress-related mental disorders.
No takes yet. Share an insight, caveat, or question.
Blaskovich et al. (2023) conducted a cross-sectional in Stress-related mental disorders (n=83). Stress-related mental disorders vs. Healthy controls was evaluated on Macrostructural sleep characteristics and spectral power differences (low vs high frequency power ratio). Patients with stress-related mental disorders exhibited a flattened age-related decline in the low-versus-high frequency EEG power ratio and higher pre-sleep heart rate compared to healthy controls.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: