Key result
Anti-Xa assays fail equivalence with LC-MS/MS, underestimating apixaban levels by ~15%.
Why the study?
Anti-Xa assays are routinely used to measure rivaroxaban and apixaban plasma concentrations despite a lack of data on assay equivalence, particularly at clinical decision cut-offs.
Do different anti-Xa assays and dRVVT provide equivalent results to LC-MS/MS for measuring rivaroxaban and apixaban concentrations in patients with atrial fibrillation?
Observational (n=122)
Yes
Do different anti-Xa assays and dRVVT provide equivalent results to LC-MS/MS for measuring rivaroxaban and apixaban concentrations in patients with atrial fibrillation?
Anti-Xa assays may significantly underestimate apixaban concentrations compared to LC-MS/MS, highlighting a potential risk for clinical decision-making in emergency situations.
Anti-Xa assays may underestimate apixaban; cross-sectional data leaves open assay validation needs versus LC-MS/MS in AF.
Background/Objectives: Different anti-Xa assays are routinely used to evaluate the plasma concentrations of direct factor X inhibitors (DXIs) rivaroxaban and apixaban, despite a lack of data on assay equivalence. Information on assay performance is particularly important at clinical decision cut-offs, such as 50 ng/mL or 30 ng/mL. The aim of this study was to evaluate the equivalence of different anti-Xa assays with the reference LC-MS/MS method for measuring rivaroxaban and apixaban concentrations in a multicenter study. In addition, the usefulness of the dRVVT as a simple coagulation test for emergency situations was evaluated. Methods: We included 122 patients with atrial fibrillation. Trough and peak blood samples were collected from 60 patients treated with rivaroxaban and 62 patients treated with apixaban. Rivaroxaban and apixaban plasma levels were measured by LC–MS/MS. Different anti-Xa assays were used in three laboratories to evaluate equivalence. Results: The concentrations in the analyzed samples ranged from 2 to 781 ng/mL for rivaroxaban and 9 to 568 ng/mL for apixaban. Only one of the anti-Xa assays gave equivalent results to LC-MS/MS for rivaroxaban, and none for apixaban. All anti-Xa assays significantly underestimated apixaban concentration, with a proportional bias between 10% and 20%. A high correlation was found between DXI concentration and dRVVT clotting time, but dRVVT was not consistently prolonged at clinically relevant DXI concentrations in plasma. Conclusions: Only one of the anti-Xa assays showed equivalence with LC-MS/MS for rivaroxaban, and none for apixaban. Several anti-Xa assays provided reliable results for rivaroxaban in the range of clinically relevant cut-off values, but none for apixaban, which could expose patients to a higher risk of bleeding and urgently needs further clinical research. The dRVVT test was not sensitive enough for reliable detection of clinically relevant DXI plasma concentrations and therefore cannot replace the anti-Xa assay in emergency situations.
No takes yet. Share an insight, caveat, or question.
Mijovski et al. (2025) conducted an observational in Atrial fibrillation (n=122). Anti-Xa assays and diluted Russell's viper venom time (dRVVT) vs. LC-MS/MS was evaluated on Equivalence of different anti-Xa assays with the reference LC-MS/MS method for measuring rivaroxaban and apixaban concentrations. Only one anti-Xa assay showed equivalence with LC-MS/MS for rivaroxaban, and none for apixaban, which was significantly underestimated with a proportional bias between 10% and 20%.