Key result
Preeclampsia is linked to ~2-fold higher resting augmentation index compared to healthy pregnancy.
Why the study?
Early recognition of systemic hemodynamic changes resulting from uteroplacental circulation disturbance in preeclampsia is important for appropriate treatment and prevention, but hemodynamic changes during a roll-over test using applanation tonometry had not been assessed.
Does combining a roll-over test with radial artery applanation tonometry improve the detection of hemodynamic and arterial stiffness differences between preeclamptic and healthy normotensive pregnant women?
Case-Control (n=35)
Operators were unaware of the grouping status of the patients (preeclamptic or not)
No
Does combining a roll-over test with radial artery applanation tonometry improve the detection of hemodynamic and arterial stiffness differences between preeclamptic and healthy normotensive pregnant women?
While radial applanation tonometry detects elevated arterial stiffness and central pressures at rest in preeclamptic women compared to healthy controls, combining it with a postural roll-over test does not provide additional diagnostic sensitivity.
Answers are grounded in this paper and cite their sources.
Radial applanation tonometry detects higher resting AIx in preeclampsia; leaves open whether roll-over testing adds diagnostic value.
Background: The early recognition of systemic hemodynamic changes resulting from uteroplacental circulation disturbance in preeclampsia (PE) is of great importance for its appropriate treatment and prevention. The aim of the present study was to assess the hemodynamic changes during a roll-over test in healthy normotensive and preeclamptic pregnant women using applanation tonometry. Patients and methods: Healthy pregnant and PE women in their third trimester were studied. First, applanation tonometry was performed in a resting state on the right radial artery of each subject. In the second phase, the measurements were repeated in the left-lateral position and 5 min after turning each patient into a supine position (roll-over test = ROT). The systolic and diastolic central and peripheral blood pressures, pulse pressures, and augmentation index (AIx75) values were registered for all phases. Results: A total of 21 PE and 14 healthy pregnant women entered this study. At rest, the PE patients had higher systolic, diastolic, and mean blood pressures; the preeclamptic patients had higher peripheral and central blood pressure and pulse pressure values compared to the healthy controls. A statistically significant difference was found between the augmentation index (AIX-75) values for the preeclamptic and healthy pregnant women (healthy pregnant: 9.0 ± 2.4 vs. preeclamptic: 18.9 ± 6.0; p = 0.019). During the ROT, no significant differences could be detected in the applanation tonometry parameters within the groups. The differences between the PE and healthy pregnant women continued to exist in the left-lateral and supine positions during the roll-over test. Conclusions: This is the first study combining a roll-over test and arterial stiffness measurements in healthy pregnant females and in those with PE. Although we can confirm that arterial stiffness measurements can be used to detect hemodynamic changes in pregnant women with PE, combining it with a roll-over test is unsuitable for improving the method’s sensitivity.
No takes yet. Share an insight, caveat, or question.
Szatmári et al. (2025) conducted a case-control in Preeclampsia in the third trimester of pregnancy (n=35). Preeclampsia evaluated by applanation tonometry during a roll-over test vs. Healthy normotensive pregnancy was evaluated on Resting augmentation index normalized for heart rate (AIx-75) via radial artery applanation tonometry (p=0.019). Preeclamptic women had higher resting augmentation index (AIx-75) than healthy controls, with no significant within-group changes during the roll-over test.
Synapse has enriched 10 related papers. Consider them for comparative context: