Key result
Research-grade systolic blood pressure was 0.1 mm Hg higher than routine care measurements, demonstrating high within-person variation and moderate correlation.
Why the study?
Accurate blood pressure measurement is essential, but prior studies noted differences between routine care and research measurements. The study evaluated agreement between these methods in a system with initiatives to standardize routine care measurements.
Does research-grade blood pressure measurement differ from routine clinical care blood pressure measurement in older adults with hypertension?
Cross-Sectional (n=309)
Does research-grade blood pressure measurement differ from routine clinical care blood pressure measurement in older adults with hypertension?
Answers are grounded in this paper and cite their sources.
Despite small mean differences between routine care and research-grade BP measurements, high within-person variation highlights the need for standardized BP measurement protocols in clinical practice.
BACKGROUND: Accurate blood pressure (BP) measurement is essential to identify and manage hypertension. Prior studies have reported a difference between BP measured in routine patient care and in research studies. We aimed to investigate the agreement between BP measured in routine care and research-grade BP in Kaiser Permanente Southern California, a large, integrated healthcare system with initiatives to standardize BP measurements during routine patient care visits. METHODS: We included adults ≥65 years old with hypertension, taking antihypertensive medication, and participating in the Ambulatory Blood Pressure in Older Adults (AMBROSIA) study in 2019-2021. Clinic BP from routine care visits was extracted from the electronic health record. Research-grade BP was obtained by trained AMBROSIA study staff via an automatic oscillometric device. The mean difference between routine care and research-grade BP, limits of agreement, and correlation were assessed. RESULTS: We included 309 participants (mean age 75 years; 54% female; 49% non-Hispanic white). Compared with measurements from routine care, mean research-grade systolic BP (SBP) was 0.1 mm Hg higher (95% CI: -1.5 to 1.8) and diastolic BP (DBP) was 0.4 mm Hg lower (95% CI: -1.6 to 0.7). Limits of agreement were -29 to 30 mm Hg for SBP and -21 to 20 mm Hg for DBP. The intraclass correlation coefficient was 0.42 (95% CI: 0.33 to 0.51) for SBP and 0.43 (95% CI: 0.34 to 0.52) for DBP. CONCLUSIONS: High within-person variation and moderate correlation were present between BP measured in routine care and following a research protocol suggesting the importance of standardized measurements.
No takes yet. Share an insight, caveat, or question.
Sanders et al. (2023) conducted a cross-sectional in Hypertension (n=309). Research-grade blood pressure measurement vs. Routine care blood pressure measurement was evaluated on Mean difference between routine care and research-grade systolic blood pressure (MD 0.1 mm Hg, 95% CI -1.5 to 1.8). Research-grade systolic blood pressure was 0.1 mm Hg higher than routine care measurements, demonstrating high within-person variation and moderate correlation.
Synapse has enriched 10 related papers. Consider them for comparative context: