Why the study?
Does pulsed Doppler mapping accurately estimate stenotic aortic valve area compared to invasive catheterisation in adult patients with aortic valve stenosis?
Does pulsed Doppler mapping accurately estimate stenotic aortic valve area compared to invasive catheterisation in adult patients with aortic valve stenosis?
Pulsed Doppler mapping provides a reliable, non-invasive method for estimating stenotic aortic valve area that is consistent with invasive catheterization measurements.
Answers are grounded in this paper and cite their sources.
May support non-invasive aortic stenosis assessment; leaves open prospective validation in larger cohorts.
A new pulsed Doppler mapping technique has been used to measure the severity of aortic valve stenosis. The Doppler examination was performed at the site of the aortic orifice in the parasternal short axis echocardiographic view and the method was based on the detection of the area of systolic flow through the stenotic orifice. This area was derived by planimetry and the measurements obtained by the Doppler method were compared with the aortic valve area calculated at catheterisation according to the Gorlin formula. The method was applicable in 41 of the 44 patients studied. The Doppler data were consistent with the haemodynamic measurements even in patients with decreased cardiac index. It is concluded that this new application of the flow mapping procedure is reliable and is easily applied to adult patients with a wide range of clinical conditions.
No takes yet. Share an insight, caveat, or question.
Veyrat et al. (1987) studied this question.