Why the study?
Which dialysis unit blood pressure measurement best reflects 48-h interdialytic ambulatory blood pressure in chronic haemodialysis patients?
Which dialysis unit blood pressure measurement best reflects 48-h interdialytic ambulatory blood pressure in chronic haemodialysis patients?
In chronic haemodialysis patients, the 20-minute post-dialysis blood pressure reading is the best representation of interdialytic pressure, as predialysis readings often overestimate it due to a white-coat effect.
Answers are grounded in this paper and cite their sources.
Supports preferring 20-min post-dialysis BP over arrival readings for interdialytic estimation in HD; leaves open outcome validation before practice change.
BACKGROUND: Hypertension in chronic haemodialysis patients contributes significantly to morbidity and mortality. Treatment decisions are usually based on predialysis readings, which may not accurately reflect control during the interdialytic period. METHODS: We studied 40 randomly selected subjects on haemodialysis and compared readings by different methods at set times during the dialysis session with the 48-h interdialytic ambulatory readings. Conventional sphygmomanometer, automated Dinamap and Tm 2421(A&D) ambulatory monitor were used for BP measurements. RESULTS: Conventional sphygmomanometry and self measured automatic readings (Dinamap) were highly correlated (systolic r=0.93, P<0.001; diastolic r=0.90, P<0.001). Mean blood pressure on arrival ((PreC(0)) 158 mmHg systolic, 80 mmHg diastolic and 106 mmHg mean) significantly overestimated the mean ambulatory reading during the 6 h prior to attendance ((preAm(6h)) systolic 147 (P<0.01), diastolic 75 (P<0.01), mean 99 (P<0.01)). Fifteen patients (41%) demonstrated a marked difference (>20/10 mmHg) between the PreC(0) and preAm(6h) (white-coat effect) persisting in seven patients (19%) after a period of rest 10 min predialysis (preC(10)) and present even in self-recorded Dinamap readings. There was a significant negative relationship between the systolic rise and the number of months on dialysis (P<0.05). Mean ambulatory BP on interdialytic day 2 was significantly greater than on day 1 whereas the awake-sleep differences were less on day 2 than day 1, both perhaps reflecting differences in volume status. The 20 min post-dialysis measurement (PoC(20)) for systolic, diastolic, and mean, unlike predialysis (PreC(0) and preC(10)), onset (onC) and end of dialysis readings (enC) did not differ significantly from 48 h interdialytic means. CONCLUSIONS: The best representation of interdialytic pressure was the 20-min post-dialysis reading. Walk-in predialysis pressures overestimate mean interdialytic pressures due to a high incidence of white-coat effect, which shows some habituation with time on dialysis. Ambulatory monitoring has a role in evaluating persistent poor blood pressure control in haemodialysis patients.
No takes yet. Share an insight, caveat, or question.
Mitra et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: