Time-specified reference standards for ambulatory blood pressure monitoring reveal upper limits below currently used thresholds for diagnosing hypertension, particularly in women.
Answers are grounded in this paper and cite their sources.
May indicate current ambulatory BP thresholds are too high for women; hypothesis-generating pending outcome validation.
To recognize the highly significant circadian variability of blood pressure (BP) is to admit that the diagnosis of hypertension should be based not just on whether a casual BP value is too high, but rather on more pertinent questions: How long is BP elevated above a given time-varying threshold? What is the excess BP? When most of the excess occurs? Answers to these questions may be obtained by establishing, first, an adequate reference BP threshold and, second, a proper measurement of BP elevation [Hermida et al. Hypertension. 2000;35:118-125]. Accordingly, we derived time-specified reference standards for BP as a function of gender. We studied 375 normotensive volunteers (200 men), 43.1±1.0 (meam±SE) years of age, without medical history of hypertension and diurnal mean of ambulatory monitored BP below 135/85 mm Hg for systolic/diastolic BP. BP was measured at 20-minute intervals during the day (07:00 to 23:00 hours) and at 30-minute intervals at night for 48 consecutive hours with an ambulatory Spacelabs 90207 device. Physical activity was simultaneously monitored by wrist actigraphy. Data from each BP series were synchronized according to the rest-activity cycle of each individual in order to avoid differences among subjects in actual times of daily activity. Data were then used to compute 90% circadian tolerance intervals for each gender separately, in keeping with the gender differences in BP previously documented [Hermida. Blood Pres Monit. 1999;4:137-147]. The method, derived on the basis of bootstrap techniques, does not need to assume normality or symmetry in the data and, therefore, it is highly appropriate to describe the circadian pattern of BP variability. Results not only reflect expected changes in the tolerance limits as a function of gender and circadian time of sampling, but also upper limits below the thresholds currently used for diagnosing hypertension, specially for women. The use of these circadian time-dependent tolerance limits for the computation of a hyperbaric index as a measure of BP excess has already been shown to provide a reproducible and high-sensitivity test for the diagnosis of hypertension [Hermida et al. Hypertension. 2000;35:118-125], that can also be used for evaluating a given patient's response to treatment. DGES, PM98-0106; PGICT00-PXI-32205PN; University of Vigo.
No takes yet. Share an insight, caveat, or question.
R HERMIDA (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: