Why the study?
Does an apical suction device improve hemodynamic parameters compared to classic posterior pericardial suture in patients with multivessel coronary disease undergoing off-pump coronary artery bypass?
Does an apical suction device improve hemodynamic parameters compared to classic posterior pericardial suture in patients with multivessel coronary disease undergoing off-pump coronary artery bypass?
The use of an apical suction device during off-pump coronary artery bypass grafting provides better hemodynamic stability compared to classic posterior pericardial suture.
Answers are grounded in this paper and cite their sources.
Apical suction was associated with better hemodynamics than pericardial suture; hypothesis-generating and requires randomized confirmation before practice change.
Hemodynamic changes during heart luxation and stabilization are major problems in off-pump coronary artery bypass surgery. The hemodynamic effects of an apical suction device were compared with those of the classic posterior pericardial suture in 45 patients with multivessel coronary disease undergoing off-pump coronary artery bypass. Mean age was 63.78 +/- 8.11 years; 31 patients were male and 14 were female. Transesophageal Doppler echocardiography was used for hemodynamic monitoring. All hemodynamic parameters were significantly better when the apical suction device was used to position the heart for anastomoses on the posterior descending and circumflex arteries.
No takes yet. Share an insight, caveat, or question.
Üstünsoy et al. (2007) studied this question.