Key result
Off-pump CABG is associated with ~49% lower need for pharmacological support vs. on-pump CABG.
Why the study?
Improved myocardial protection by performing CABG on the beating heart compared to on-pump CABG was assessed due to potential hemodynamic differences.
Does off-pump CABG improve hemodynamic outcomes and myocardial protection compared to on-pump CABG in patients undergoing surgical revascularization?
Cohort (n=90)
Does off-pump CABG improve hemodynamic outcomes and myocardial protection compared to on-pump CABG in patients undergoing surgical revascularization?
Answers are grounded in this paper and cite their sources.
Off-pump CABG provides similar hemodynamic outcomes to on-pump CABG but significantly reduces the need for postoperative inotropic support and myocardial injury.
OBJECTIVE: The objective of this study was to assess improved myocardial protection by performing coronary artery bypass grafting (CABG) on the beating heart. A case-matched study was conducted among patients who underwent CABG either on-pump (group 1), or off-pump (group 2). METHODS: Forty-five pairs of patients, having a similar clinical profile, were selected on the basis of five variables: age, gender, body surface area, ejection fraction, extent of coronary disease. Operative risk predicted by the The Society of Thoracic Surgeons national database was 1.80+/-0.35% in group 1, and 1.89+/-0.37% in group 2 (NS). Cold blood cardioplegia and 28 degrees C cardiopulmonary bypass were used in group 1. In group 2, beating heart coronary grafting was achieved with the Octopus 1 and 2 stabilizers. The average number of distal anastomoses was 2.8+/-0.1 in group 1 and 2.3+/-0.1 in group 2 (P=0.015). RESULTS: There was no significant difference among the groups regarding the trend in cardiac index, left and right ventricular stroke work indexes, and systemic and pulmonary vascular resistance indexes. However, heart rate trend was slower in group 2 (P=0.05). Pharmacological support was required in 65% of the patients in group 1, and in 33% in group 2 (P<0.001). The total amount of Dobutamine and/or Dopamine administered during the first 48 h was 3914+/-1306 gamma/kg in group 1 and 1645+/-697 gamma/kg in group 2 (P=0.049). Release of creatine kinase MB mass isoenzyme (CK-MB mass) was markedly reduced in group 2 (P<10(-4)). CONCLUSIONS: Hemodynamic outcome following off-pump CABG is similar to on-pump CABG but the need for inotropic support is significantly reduced and CPK-MB mass release is markedly lower.
No takes yet. Share an insight, caveat, or question.
Yves Louagie (2002) conducted a cohort in Coronary artery disease requiring CABG (n=90). Off-pump CABG vs. On-pump CABG was evaluated on Requirement for pharmacological support (p=<0.001). Off-pump CABG yielded similar hemodynamic outcomes to on-pump CABG but reduced the need for pharmacological support and CK-MB release.
Synapse has enriched 10 related papers. Consider them for comparative context: