Why the study?
Does ECG-gated CT accurately correlate with right heart catheterization for assessing right ventricular function and pulmonary artery hemodynamics in patients with pulmonary hypertension?
Does ECG-gated CT accurately correlate with right heart catheterization for assessing right ventricular function and pulmonary artery hemodynamics in patients with pulmonary hypertension?
ECG-gated CT functional parameters correlate significantly with invasive right heart catheterization measurements, suggesting utility for non-invasive evaluation of patients with pulmonary hypertension.
May support non-invasive PH evaluation; leaves open prospective validation against catheterization.
BACKGROUND: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. PURPOSE: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. MATERIAL AND METHODS: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. RESULTS: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P = 0.005) correlated equally with RHC-CO. CONCLUSION: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for evaluating and following patients with PH.
No takes yet. Share an insight, caveat, or question.
Abel et al. (2012) studied this question.