Authors
The flexural behavior of an ultrahigh-performance concrete (UHPC) was investigated through the testing and related analysis of a full-scale prestressed I-girder. A 28ksi(193MPa) compressive strength steel fiber reinforced concrete was used to fabricate an 80ft(24.4m) long AASHTO Type II girder containing 26 prestressing strands and no mild steel reinforcement. Intermediate and final behaviors, including cracking, flexural stiffness, and moment capacity, were investigated. Test results are compared to predictions based on standard analytical procedures. A relationship between tensile strain and crack spacing is developed. The uniaxial stress-strain response of UHPC when subjected to flexural stresses in an I-girder is determined and is verified to be representative of both the stress and flexural stiffness behaviors of the girder. A flexural design philosophy for this type of girder is proposed.
No takes yet. Share an insight, caveat, or question.
Benjamin A. Graybeal (2008) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: