Why the study?
Differences in diagnostic accuracy between hyperemic and resting angiography-derived index of microcirculatory resistance (xaIMR) remain underexplored.
Does x-ray angiography-derived IMR (hyperemic and resting) accurately assess coronary microcirculatory resistance compared to wire-based IMR in patients with chronic coronary syndrome?
Does x-ray angiography-derived IMR (hyperemic and resting) accurately assess coronary microcirculatory resistance compared to wire-based IMR in patients with chronic coronary syndrome?
Hyperemic angiography-derived IMR is a reliable, noninvasive alternative to wire-based IMR, offering superior diagnostic accuracy compared to resting angiography-derived IMR, especially in patients with reduced coronary flow reserve.
May favor hyperemic over resting angio-derived IMR as a wire-free option; leaves open outcome trials before practice change.
Background Angiography‐derived index of microcirculatory resistance (IMR) has emerged as a feasible alternative to wire‐based IMR, due to the elimination of specialized wire and simplifying of the procedure. However, the differences in diagnostic accuracy between hyperemic and resting angiography with this technology remain underexplored. Methods This prospective, multicenter study was conducted to evaluate the feasibility and diagnostic accuracy of x‐ray angiography–derived IMR (xaIMR) in patients with chronic coronary syndrome using wire‐based functional indices as the reference. Angiography‐derived functional indices were calculated using a computational fluid dynamics model. The xaIMR indices were derived from hyperemic and resting angiography, respectively. Results A total of 139 vessels were included in the analysis of the present study. Both hyperemic xaIMR ( r =0.82; P <0.001) and resting xaIMR (R‐xaIMR) ( r =0.25; P =0.003) exhibited positive linear correlations with wire‐based IMR. Notably, hyperemic xaIMR was associated with a higher diagnostic yield (area under the receiver operating characteristic curve) than resting xaIMR (area under the receiver operating characteristics curve, 0.95 versus 0.72; P <0.001). Significant differences in diagnostic yield between these modalities were observed in vessels with compromised coronary flow reserve (<2.0). In contrast, such differences were not observed in vessels with normal coronary flow reserve (≥2.0). Conclusions xaIMR, especially derived from hyperemic angiography, is a reliable, noninvasive alternative to wire‐based IMR for assessing coronary microcirculatory resistance in chronic coronary syndrome. However, resting angiography‐derived xaIMR may have limited diagnostic accuracy in patients with reduced coronary flow reserve. Further studies are warranted to validate these findings in broader populations.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: