Why the study?
Does an automated respiratory variation monitoring device provide comparable measurements of difference in pulse pressure compared to manual assessment in intraoperative patients?
Does an automated respiratory variation monitoring device provide comparable measurements of difference in pulse pressure compared to manual assessment in intraoperative patients?
An automated algorithm for monitoring difference in pulse pressure provides measurements comparable to manual assessment, and the inclusion of airway pressure signals may not be necessary.
Answers are grounded in this paper and cite their sources.
May support automated RV monitoring as manual alternative intraoperatively; leaves open larger validation trials before routine adoption.
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.
No takes yet. Share an insight, caveat, or question.
Pestel et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: