Why the study?
Does 60° head-up tilt alter open- and closed-loop dynamic cardiac baroreflex gains in healthy men?
Does 60° head-up tilt alter open- and closed-loop dynamic cardiac baroreflex gains in healthy men?
Open-loop cardiac baroreflex gain is enhanced during orthostatic stress, suggesting that spontaneous closed-loop analyses may not accurately represent baroreflex characteristics under these conditions.
Answers are grounded in this paper and cite their sources.
Closed-loop baroreflex analyses may underestimate gain during orthostasis; leaves open whether open-loop measures better inform clinical baroreflex assessment in patients.
The neural interaction between the cardiopulmonary and arterial baroreflex may be critical for the regulation of blood pressure during orthostatic stress. However, studies have reported conflicting results: some indicate increases and others decreases in cardiac baroreflex sensitivity (i.e., gain) with cardiopulmonary unloading. Thus the effect of orthostatic stress-induced central hypovolemia on regulation of heart rate via the arterial baroreflex remains unclear. We sought to comprehensively assess baroreflex function during orthostatic stress by identifying and comparing open- and closed-loop dynamic cardiac baroreflex gains at supine rest and during 60° head-up tilt (HUT) in 10 healthy men. Closed-loop dynamic "spontaneous" cardiac baroreflex sensitivities were calculated by the sequence technique and transfer function and compared with two open-loop carotid-cardiac baroreflex measures using the neck chamber system: 1) a binary white-noise method and 2) a rapid-pulse neck pressure-neck suction technique. The gain from the sequence technique was decreased from -1.19 ± 0.14 beats·min(-1)·mmHg(-1) at rest to -0.78 ± 0.10 beats·min(-1)·mmHg(-1) during HUT (P = 0.005). Similarly, closed-loop low-frequency baroreflex transfer function gain was reduced during HUT (P = 0.033). In contrast, open-loop low-frequency transfer function gain between estimated carotid sinus pressure and heart rate during white-noise stimulation was augmented during HUT (P = 0.01). This result was consistent with the maximal gain of the carotid-cardiac baroreflex stimulus-response curve (from 0.47 ± 0.15 beats·min(-1)·mmHg(-1) at rest to 0.60 ± 0.20 beats·min(-1)·mmHg(-1) at HUT, P = 0.037). These findings suggest that open-loop cardiac baroreflex gain was enhanced during HUT. Moreover, under closed-loop conditions, spontaneous baroreflex analyses without external stimulation may not represent open-loop cardiac baroreflex characteristics during orthostatic stress.
No takes yet. Share an insight, caveat, or question.
AKIMOTO et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: