Pilot technical evaluation demonstrates enhanced lumbar CT measurement availability using vision-language model preprocessing, indicating improved robustness for automated osteoporosis screening.
Automated lumbar computed tomography (CT) Hounsfield unit (HU) measurement can support opportunistic osteoporosis screening, but heterogeneous Digital Imaging and Communications in Medicine (DICOM) inputs often disrupt automated workflows before measurement. We evaluated a local Qwen2.5-VL-7B vision-language model (VLM)-assisted front end for suitability routing, input planning, and HU-traceable DICOM-derived field-of-view/orientation adaptation upstream of an unchanged single-slice lumbar CT HU workflow. The VLM was restricted to routing and planning. In a 20-case FUJIFILM pilot cohort, observed HU output availability was higher with the front-end-assisted route than with direct processing (12/20 versus 5/20), while paired automatic-success cases showed excellent agreement with post hoc manual ImageJ (version 1.54g) measurements (ICC(A,1) = 0.997; MAE = 4.64 HU). Public DICOM stress testing further demonstrated improved workflow robustness across heterogeneous datasets. These findings support the use of a deployment-oriented front-end strategy to improve the auditability and robustness of automated lumbar CT HU measurement while preserving an unchanged downstream measurement workflow.
No takes yet. Share an insight, caveat, or question.
Ye et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: