Key result
Sinus rhythm during cryoballoon ablation predicted a significantly higher real-time observation rate of time-to pulmonary vein isolation compared to atrial fibrillation (86.3% vs 75.5%; p<0.001).
Why the study?
It was unknown whether correct pulmonary vein electrogram interpretation and real-time observation rate of pulmonary vein isolation depend on atrial rhythm during cryoballoon ablation.
Does performing cryoballoon ablation during sinus rhythm improve the real-time observation rate of time-to pulmonary vein isolation compared to atrial fibrillation in patients undergoing PVI?
Observational (n=157)
Does performing cryoballoon ablation during sinus rhythm improve the real-time observation rate of time-to pulmonary vein isolation compared to atrial fibrillation in patients undergoing PVI?
Performing cryoballoon ablation during sinus rhythm rather than atrial fibrillation significantly increases the ability to observe real-time pulmonary vein isolation, facilitating cryoenergy titration.
Associated with higher real-time PVI observation in sinus rhythm; hypothesis-generating for rhythm-targeted strategies in prospective trials.
PURPOSE: Real-time observation of pulmonary vein (PV) potentials with a spiral mapping catheter has emerged as a key electrogram-based procedural parameter to estimate lesion quality and titrate cryoenergy application during PV isolation (PVI) with the cryoballoon. Whether correct PV electrogram interpretation and thus PVI real-time observation rate depends on atrial rhythm during cryoballoon PVI is unknown. We compared observation rates of time-to PV isolation (TTI) during sinus rhythm (SR group) and during atrial fibrillation (AFib group) in cryoballoon PVI. METHODS: We prospectively included 157 consecutive patients undergoing cryoballoon PVI and compared the incidence of PVI real-time recording of each pulmonary vein during SR and in AFib. RESULTS: Overall PVI real-time observation rate was 82.1% (491/598 PV) with significantly higher TTI observation rate in the SR group (315/365 PV, 86.3%) compared to the AFib group (176/233 PV, 75.5%; p < 0.001). Per vein analysis demonstrated that only TTI observation rate in the left superior pulmonary vein (LSPV) was significantly higher during SR (85/92, 92.4%) compared to AFib (37/54, 68.5%; p < 0.001). Regression analysis revealed that atrial rhythm is a strong and independent predictor of PVI real-time observation in the LSPV with an odds ratio of 4.98 (95%-CI: 1.86-13.34, p = 0.001) to detect TTI during SR. CONCLUSIONS: Our results demonstrate that correct interpretation of PV electrograms and thus PVI real-time observation is more likely in SR than in AFib. Hence, cardioversion of patients in AFib at the beginning of the procedure should be considered to yield higher PVI real-time observation rates facilitating TTI guided cryoenergy titration.
No takes yet. Share an insight, caveat, or question.
Pott et al. (2019) conducted an observational in Atrial fibrillation undergoing cryoballoon pulmonary vein isolation (n=157). Sinus rhythm vs. Atrial fibrillation was evaluated on Real-time observation rate of time-to pulmonary vein isolation (OR 4.98, 95% CI 1.86-13.34, p=<0.001). Sinus rhythm during cryoballoon ablation predicted a significantly higher real-time observation rate of time-to pulmonary vein isolation compared to atrial fibrillation (86.3% vs 75.5%; p<0.001).