Key result
Low QRS voltage is linked to ~5.3-fold higher adverse events in normotensive pulmonary embolism.
Why the study?
This study aimed to explore a rapid risk model to predict in-hospital adverse events for normotensive patients with acute pulmonary embolism.
Does a novel risk model combining admission ECG low QRS voltage and biomarkers (age-adjusted D-dimer, troponin, PaO2/FiO2) improve the prediction of in-hospital adverse events compared to PESI, sPESI, Bova, and FAST scores in normotensive patients with acute pulmonary embolism?
Cohort (n=213)
Blind ECG interpretation by at least two experienced cardiologists
No
Does a novel risk model combining admission ECG low QRS voltage and biomarkers (age-adjusted D-dimer, troponin, PaO2/FiO2) improve the prediction of in-hospital adverse events compared to PESI, sPESI, Bova, and FAST scores in normotensive patients with acute pulmonary embolism?
A novel risk model combining low QRS voltage on admission ECG with age-adjusted D-dimer, troponin, and PaO2/FiO2 < 300 provides superior discrimination (AUC 0.847) compared to PESI, sPESI, Bova, and FAST scores for predicting in-hospital adverse events in normotensive acute pulmonary embolism patients.
Answers are grounded in this paper and cite their sources.
May support refined risk stratification in normotensive PE; leaves open prospective validation before clinical adoption.
Background The patients with suspected pulmonary embolism (PE) were usually screened using electrocardiogram (ECG) and blood panel of D‐dimer, troponin, and blood gas analysis in the emergency. Objectives This study aimed to explore a rapid risk model to predict in‐hospital adverse events for normotensive PE patients. Methods Patients with acute PE having normal blood pressure on appearance were retrospectively enrolled at China‐Japan Friendship Hospital from January 2017 to February 2020. The in‐hospital adverse events were defined as death and clinical deterioration during hospitalization. The risk model for in‐hospital adverse events was generated by multivariate regression analysis. The discrimination ability of the model was compared with PESI, Bova, and FAST risk score, and evaluated by the receiver operating characteristic curve (ROC), net reclassification improvement (NRI), and integrated discrimination improvement index (IDI). Results Of the 213 patients, 35 (16.4%) experienced in‐hospital adverse events,y including 15 deaths. The average age was 69 ± 19 years, and 118 (44.6%) were females. Multiple logistic regression analysis showed that independent risk factors associated with in‐hospital adverse events were low QRS voltage in ECG (OR: 5.321; 95% CI: 1.608–7.310), positive age‐adjusted D‐dimer (OR: 2.061; 95% CI: 0.622–6.836), positive troponin (OR: 3.504; 95% CI: 1.744–8.259), and PaO 2 /FiO 2 < 300 (OR: 3.268; 95% CI: 0.978–5.260). The ROC analysis showed that the AUC of the new model (0.847, 95% CI: 0.786–0.901) was better than the PESI score (0.628, 95% CI: 0.509–0.769), the Bova score (0.701, 95% CI: 0.594–0.808), and the FAST score (0.775 95% CI: 0.690–0.859). Conclusion ECG abnormalities and biomarkers on admission may provide a rapid and effective approach to identify patients with poor prognoses during hospitalization.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2025) conducted a cohort in Normotensive acute pulmonary embolism (SBP > 90 mmHg) (n=213). Admission ECG abnormalities and biomarker risk model (low QRS voltage, positive age-adjusted D-dimer, positive troponin, and PaO2/FiO2 < 300) vs. PESI, sPESI, Bova, and modified FAST risk scores was evaluated on In-hospital adverse events (composite of in-hospital death and clinical deterioration including hypotension, catecholamine use, thrombolysis, mechanical ventilation, or CPR) (OR 5.321 (for low QRS voltage in multivariate model); Model AUC 0.847, 95% CI 1.608-7.310, p=0.033). A novel risk model combining low QRS voltage, positive age-adjusted D-dimer, positive troponin, and PaO2/FiO2 <300 predicted in-hospital adverse events in normotensive PE with an AUC of 0.847.