Key result
Tenzingplasty achieves ~81% final reperfusion in acutely symptomatic intracranial atherosclerotic disease.
Why the study?
Does Tenzingplasty improve luminal caliber and flow restoration in patients with acutely symptomatic intracranial atherosclerotic disease?
Observational (n=53)
Does Tenzingplasty improve luminal caliber and flow restoration in patients with acutely symptomatic intracranial atherosclerotic disease?
Answers are grounded in this paper and cite their sources.
Tenzingplasty appears to be a feasible and safe rescue therapy for improving luminal caliber and flow restoration in acutely symptomatic intracranial atherosclerotic disease.
INTRODUCTION: Catheter-mediated (Dotter) angioplasty has been previously described for extracranial/peripheral arteries. Tenzing (Route 92 Medical, San Mateo, California, USA), a shelf-reducing delivery catheter, has an atraumatic tapered distal tip that progressively enlarges to maximal outer diameter of 1.2 mm (Tenzing 5), 1.6 mm (Tenzing 7), and 2.1 mm (Tenzing 8). OBJECTIVE: To report our initial experience treating acutely symptomatic intracranial atherosclerotic disease (ICAD) using Dotter angioplasty with Tenzing (Tenzingplasty). METHODS: After institutional review board approvals, we retrospectively reviewed clinical and procedural data of patients with underlying ICAD treated with off-label Tenzingplasty between 2022 and 2025, either as part of endovascular treatment for large vessel occlusion, or after medical therapy failure <96 hours from presentation. RESULTS: We identified 53 consecutive patients with symptomatic ICAD who underwent Tenzingplasty, median (IQR) age 63 (57-70) years, 29 (55%) male. ICAD locations were: M1 (24), M2 (9), internal carotid artery (3), vertebral V4 segment (7), basilar (8), vertebrobasilar junction (1), and A2 anterior cerebral artery (1). First pass aspiration thrombectomy for patients with an initial modified Thrombolysis in Cerebral Infarction score 0 (without crossing the ICAD lesion) was performed in 34/53 (64%). After median 1 (IQR 1-2) Tenzingplasty pass, median (IQR) stenosis improved from 100% (95-100) to 60% (42-76) post-Tenzingplasty (P<0.0001). Subsequent balloon angioplasty or stenting was performed in 4% and 21%, respectively. Successful final reperfusion (expanded Thrombolysis in Cerebral Infarction 2b-3) was achieved in 81%, with one Tenzingplasty-related complication (a non-flow limiting dissection), and no perforations. In follow up, 25/44 (57%) had a 90-day modified Rankin Scale score of 0-2. CONCLUSION: Tenzingplasty may be a feasible and safe rescue therapy for improving luminal caliber, flow restoration, and/or lesion preparation for stenting in acutely symptomatic ICAD.
No takes yet. Share an insight, caveat, or question.
Settecase et al. (2025) conducted an observational in acute ischemic stroke with underlying intracranial atherosclerotic disease (n=53). Tenzingplasty (Dotter angioplasty using Tenzing) was evaluated on successful final reperfusion (expanded Thrombolysis in Cerebral Infarction 2b-3). Tenzingplasty for acutely symptomatic intracranial atherosclerotic disease achieved successful final reperfusion in 81% of patients and reduced median stenosis from 100% to 60%.
Synapse has enriched 10 related papers. Consider them for comparative context: