Key result
PE likelihood ratios double across successive D-dimer intervals, reaching ~1.0 at 1,000-1,499 ng/mL.
Why the study?
What are the interval likelihood ratios across eight quantitative D-dimer intervals for diagnosing acute pulmonary embolism in patients with clinically suspected PE?
Meta-Analysis (n=6,013)
Yes
What are the interval likelihood ratios across eight quantitative D-dimer intervals for diagnosing acute pulmonary embolism in patients with clinically suspected PE?
Answers are grounded in this paper and cite their sources.
Supports raising D-dimer cutoff to 1,000 ng/mL in low-probability patients; extends meta-analytic evidence on interval likelihood ratios for PE.
OBJECTIVE: The objective was to estimate D-dimer interval likelihood ratios (iLRs) for diagnosing pulmonary embolism (PE). METHODS: The authors used pooled patient-level data from five PE diagnostic management studies to estimate iLRs for the eight D-dimer intervals with boundaries 250, 500, 750, 1,000, 1,500, 2,500, and 5,000 ng/mL. Logistic regression was used to fit the data so that an interval increase corresponds to increasing the likelihood ratio by a constant factor. RESULTS: The iLR for the D-dimer interval 1,000-1,499 ng/mL was essentially 1.0 (0.98 with 95% confidence interval [CI] = 0.82-1.18). In the logistic regression model, the constant between-interval factor was 2.0 (95% CI = 1.9-2.1). Using these iLR estimates, if the pre-D-dimer probability of PE is 15%, only a D-dimer less than 500 ng/mL will result in a posttest probability below 3%; if the pretest probability is 5%, the threshold for a "negative" D-dimer is 1,000 ng/mL. CONCLUSIONS: A decision strategy based on these approximate iLRs agrees with several published strategies.
No takes yet. Share an insight, caveat, or question.
Kohn et al. (2017) conducted a meta-analysis in Suspected acute pulmonary embolism (n=6,013). Quantitative plasma D-dimer testing across eight defined concentration intervals vs. Reference standard diagnosis (CT pulmonary angiography, ventilation/perfusion scanning, or 3-month clinical follow-up) was evaluated on Diagnosis of pulmonary embolism across D-dimer intervals (interval likelihood ratio for 1,000-1,499 ng/mL and constant between-interval factor) (iLR 0.98 (between-interval factor 2.0), 95% CI 0.82-1.18). D-dimer values of 1,000-1,499 ng/mL yielded an interval likelihood ratio of 0.98 for pulmonary embolism, with likelihood ratios doubling across each successive interval.